Culligan® Series G1 Reverse Osmosis
56
Cat. No. 01021713
Alternating RO Unit Settings
RUNNING
JAN-01-12 12:01P
1. From the default home screen, press
. The screen displays the main menu.
1) GO TO RUNNING
2) GO TO OFFLINE
3) INFORMATION
>4) SETUP
2. Press
to scroll to 4) SETUP.
3. Press
to select the SETUP menu.
2) LANGUAGE
3) POWERON MODE
4) FLUSH MODES
>5) ACCESSORIES
4. Press
to select 5)ACCESSORIES. The screen displays the ac-
cessories menu.
5) PRESS GAUGES
6) TDS
7) RELAY MODE
>8) MULT UNIT RO
5. Press
to select 8)MULT UNIT RO. The screen dis-
plays the multiple unit RO settings.
Screen Display
Range
Changing the Setting
MULTI UNIT RO
SINGLE
Single
Two Pass RO
Alternating
Press
or
and then
to select the RO system
configuration.
For Two-Pass configuration, refer to the Series G1 RO Two-Pass
Kit manual (P/N 01026027).
MUL UNIT RO ROLE
MASTER
Master
Slave
If you select Alternating, press
or
and then
to select
MASTER if the selected RO will control the functions of the entire
RO system. Select SLAVE if the selected RO will be controlled by
the master RO.
NOTE The Master RO must be set up first.