176
Click
OK
to start the download process and receive files from the server. A transmitting progress
will be displayed during file transfer. Once completed, a process-completed message will pop up
to remind the user.
Click
Put
to start the upload process and transmit files to the server. A transmitting progress will
be displayed during file transfer. Once completed, a process-completed message will pop up to
remind users.
Click
Stop
to abort the current operation.
Select
Update
then press
Enter
to instruct the Managed Switch to update existing
firmware/configuration to the latest firmware/configuration received. After a successful update, a
message will pop up. The Managed Switch will need a reset to make changes effective.
4.6.3 Load Factory Settings
Load Factory Setting
will set all the configurations of the Managed Switch back to the factory
default settings, including the IP and Gateway address.
Load Factory Setting
is useful when
network administrators would like to re-configure the system. A system reset is required to make
all changes effective after Load Factory Setting.
Select
Load Factory Setting
from the
System Utility
menu and then the following screen page
appears.
Click
OK
to start loading factory settings.
4.6.4 Load Factory Settings Except Network Configuration
Load Factory Settings Except Network Configuration
will set all the configurations of the
Managed Switch back to the factory default settings. However, IP and Gateway addresses will not
restore to the factory default.
Load Factory Settings Except Network Configuration
is very useful when network
administrators need to re-
configure the system “REMOTELY” because conventional Factory Reset
will bring network settings back to default and lose all network connections.