34
To Display the Fault Code
1.
Turn off the Hot Tank Power Switch (Fig. 1)
2.
Press and hold the
“8
ounce
”
and
“10
ounce
”
buttons for five seconds (Fig. 2 & 3).
3.
The
“
Select Cup Size
”
LED will flash and the unit will make a short beep.
1.
If no faults, the LED will flash once.
2.
If a problem with the NTC control board, two flashes.
3.
If a problem with the NTC display board, three flashes.
4.
If a coffee system problem (flow meter, solenoid, tubing, etc.), four flashes.
5.
If a problem with heating system, five flashes.
6.
If a problem with the air pump, six flashes.
To Clear the Fault Code.
1.
Press and hold the
“
Brew
”
button and the
“10
ounce
”
button (Fig. 4 & 5)
2.
The unit will make a long beep. The
“
Select Cup Size
”
button will not flash.
3.
The Fault Code is cleared.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Displaying and Clearing the Fault Codes