18
6.
Cut the small plastic zip tie holding the cold control sensor bulb to the evaporator insulation (Fig. 8).
7.
Pull the sensor tube out from the evaporator insulation to remove (Fig. 9).
Note: If required, install the Sensor tube cover onto
the replacement cold control.
8.
Install the replacement cold control into the evaporator insulation until it bottoms out—approximately 5 inches (Fig. 10).
Note:
Care should be taken while installing the sensor tube that the protective cover within the evaporator insulation is in the proper
position.
8.
Install a replacement zip tie to hold the sensor within the evaporator insulation.
9.
Reinstall the wire terminals onto the cold control taking care to place in original position.
10.
Install the cold control to the plastic shelf, re
-
using the original screws.
11.
Reinstall the upper back panel.
12.
Re
-
connect the cooler to the power supply.
Note: Ensure proper thermostat setting (see section for Cold Control Adjustment).
Fig. 8
Fig. 9
Fig. 10