14
Notice:
The information and/or procedures presented in the following demonstration(s) should be performed by a trained Water Cooler
Service Technician only. Never attempt to service or repair a water cooler while it is plugged into any power supply. Prior to
any service or repair of the water cooler, ensure that the water has been completely drained from the system.
For the best tasting and highest quality water, it is recommended to change the SmartFlo
™
Water Cartridge every 12 months.
Follow the steps below to replace the SmartFlo
™.
It is recommended to empty the bottle prior to replacement of the SmartFlo
™
and bottle adaptor.
Note: A blue light above the cold water lever will alert you when the SmartFlo
™
Water Cartridge should be replaced. The sys-
tem has been pre
-
set to provide indication after a period of 12 months of use. Users may operate the cooler as normal until the
bottle has been emptied.
Note: To reset the timer system, the SmartFlo
™
must be removed from the dispenser for a minimum of 15 seconds while the unit
is connected to the mains power supply.
1.
Open Dispenser door (Fig. 1). Slide door upward to access bottle area. Turn off the hot tank power switch (Fig. 2) and unplug
the water cooler (Fig. 3).
CAUTION: WATER IN HOT TANK IS VERY HOT AND CAN CAUSE SEVERE BURNS. ALLOW SUFFICIENT TIME FOR
THE HOT WATER TO COOL BEFORE DRAINING (1
-
2 HOURS)
2.
Take bottle out from the base. (Caution: don
’
t break the corrugated tube.) Remove the connecter from adapter. Fig. 4).
3.
Place a glass or other container below the water outlets (to catch drips) and unlatch the blue locking clip located
near the front of the cooler to release the water tubing (Fig. 5).
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Replacing the SmartFlo
™