64
F3 Robot Arm User Guide
99-05-31
Verifying Installation
Note: Refer to and follow the Safety Operation Checks on page 28 before
operating the arm.
Checking Arm and Controller Installation
Verify that following:
•
The robot has been mounted securely with four M12 fasteners each with
at least 2 cm (0.8”) of thread engagement.
•
The umbilical cable is connected at both ends, provided adequate
clearance and otherwise protected from damage.
•
The fuses and voltage selector have been properly installed.
•
The system has been connected to a properly grounded AC outlet of
correct electrical rating.
•
Robcomm 3 has been installed on a PC which is connected to the
controller via the front panel console port.
Note: If you do not have a computer with Robcomm 3 or compatible
terminal emulator, you can test the arm using a teach pendant.