xiv
99-05-31
Use Correct Power with GPIO and SYSIO
Do not use the internal 24V power supply for any functions when interfacing
to the GPIO or SYSIO. Use an external power supply.
Shut Down Properly
To shut down the system:
1.
Turn off arm power by hitting an e-stop.
2.
Properly shut down the operating system with the command
shutdown now
.
3.
Turn off the controller at the controller’s main power switch.