MISCELLANEOUS PANEL OPTIONS # 2
This address (P170E) is used to select the second set of optional panel functions.
P170E 1E
Panel Tamper NC or EOL - Default
on
2E
Installer Lockout - Default off
3E
Disable Mains Fail Test - Default off
4E
Arm only if sealed - Default
on
5E
No audible keypad beep on supervised radio fault - Default off
6E
No audible keypad beep for zone Inactivity Timeout - Default off
7E
“Control” button disables Day Zones( CHIME ) - Default
on
8E
Silent 24 Hour Alarms (No keypad Buzzer) - Default off
Option 1
Panel Tamper NC or EOL
- The Tamper input on the PW-8 control board (Tmp) requires sealing to
clear the panel tamper alarm. If option 1 is on the panel must see a 2k2 resistor (EOL) across the Tmp &
0V terminals to ensure the tamper is sealed. If this option is turned off the a simple short circuit (NC) is
all that is required to seal the panel tamper.
Option 2
Installer Lockout
- Normally, if the panel is unset and powered up with the panel tamper open (in
alarm) then the panel will automatically go into installer program mode. If this option is on, the panel will
not automatically go into program mode and the only valid method of accessing program mode is via the
installer code.
Option 3
Disable Mains Fail Test -
If the panel must be run off a DC supply but the supply is too low to be wired
into the AC terminals then this option completely disables the mains fail monitoring so the panel will not
give a continuous system alarm.
Option 4
Arm only if sealed -
If this option is on then the panel can only be armed if all zones are sealed( Ready
LED On), with the exception of those zones which can be unsealed if programmed at address P145E.
Option 5
No audible keypad beep on supervised radio fault -
If a supervised radio detector fails to send a test
signal within a preset period, an alarm will be generated. A supervised alarm will cause the system LED
on the keypad to flash. If this option is off then all keypad buzzers will also sound continuously to warn of
the problem. If this option is on, the buzzers will not sound on a supervised alarm but the system LED
will still flash.
Option 6
No audible keypad beep on zone inactivity timeout -
If a zone is set for inactivity monitoring (P150E)
and it does not unseal at least once during the timeout period (P240E) an alarm will be generated. An
inactivity timeout will cause the trouble LED on the keypad to flash and the zone led that failed will be on
solid. If this option is off then all keypad buzzers will also sound continuously to warn of the problem. If
this option is on, the buzzers will not sound on a zone inactivity alarm but the trouble LED will still flash.
Option 7
“CONTROL” function disables day zones( CHIME )
- This option will disable the day zone monitoring
when “Control” is on. It is used to stop day zone beeps from occurring at the keypad or operating an
output when not needed. To initiate the “Control” function the operator must press The “Control” button
followed by the “Program” button. When the “Control” function is On the Program LED will flash.
Option 8
Silent 24 Hour Alarms (No keypad Buzzer)
- If this option is on then any 24 hour alarms (P129,140 or
141E) will not cause the keypad buzzer to sound i.e. silent alarm.
- - 3 - - - - -
Misc Option B
1 - - 4 - - 7 -
Misc Option A