Page 20
PARTITION “B” OPTIONS
PARTITION “B” OPTIONS - P120E
This address allows modification of how Partition “B” arming, STAY and control keys work at the keypad.
P120E 1E
“ARM” button required before code to set- Default off
2E
“STAY” button required before code to turn on Stay Mode- Default off
3E
“CODE” required to arm- Default off
4E
“ARM” button can disarm system during exit delay - Default
on
5E
“STAY” button can disarm Stay Mode at any time- Default
on
6E
No Exit Beeps to keypads in Stay Mode- Default off
7E
Key-switch Enabled- Default
on
8E
Key-switch Mode- Default off
Option 1
“ARM” button required before code to set
- This option determines if the “ARM” button must be
pressed before a code is entered to set Area “B”. If a keypad is assigned to both Partitions, this
option should be set to allow individual arming of each area. This option disables the Arm button from
disarming during the exit delay.
Option 2
“STAY” button required before code to set
- This option determines if the “STAY” button must be
pressed before a code is entered to set Area “B” Stay Mode. If a keypad is assigned to both
Partitions, this option should be set to allow individual arming of Stay Mode for each area.
Option 3
“CODE” required to set
- If this option is set, the “ARM” button is disabled and the panel requires a
code to arm as well as disarm.
Option 4 “
ARM” button can disarm during exit delay
- If this option is on then the “arm” button can disarm
Partition “B” during the exit delay time with a single press of the button. If the option is off then the
alarm can only be unset by a valid code, even during the exit delay time.
Option 5
“STAY” button can disarm Stay Mode
- This option allows the “Stay” button to disarm STAY mode
at any time (including when Stay Mode is fully set). If the option is off then Stay Mode can only be
unset by a valid code. This feature is defaulted to keypad addresses 1 & 4 ( 4 being the default
address for the STAY key station).
Option 6
No Exit Beeps to keypads in Stay Mode -
This option stops the exit beeps from occurring at all
keypads when Stay Mode is set. Normally used for silent night arming.
Option 7
Enable Partition “B” Key-switch -
If this option is turned on then the system tamper input (Tmp)
becomes a Dual End of Line Input (Refer to Type 4 drawing on Page 4 for wiring details). The high
input 8K2 is reserved for Partition “B” key-switch operation. An open circuit will still be seen as a
system tamper.
Option 8
Key-switch Mode -
If this option is On then the key-switch has a toggle function (ie the arm/disarm
state will follow the key-switch state). If Off then the key-switch is momentary (ie each single pulse
will change the arm/disarm state). The panel tamper input is used to provide the key-switch function.
PARTITION “B” OUTPUT OPTIONS
PARTITION “B” OUTPUT OPTIONS - P121E - P128E
This block of addresses sets a number of output options which are specific and unique to the operation of partition
or Area "B". Activity in Areas "A" will have no direct effect on the options set at these addresses.
P121E
1E
Arm status to output- Default off
2E
Stay Mode on status to output- Default off
3E
Disarm status to output - Default off
- - - 4 5 - - -
AreaB Option