Page 46
AUTO-ANSWER RING COUNT
The auto-answer ring count is the number of rings the panel must count before answering an in-coming call. For Fax
defeat to work the auto-answer ring count must be set to a number other than “0”. (typically 25 rings)
P249E Auto-answer Ring Count -
Value 0-99 (0= Auto-answer disabled) - Default =
8
MAINS FAIL REPORTING DELAY
This address (P319E) is used to set a timer that delays the reporting of Mains Failure to a Monitoring Station. If the
mains voltage returns before the timer expires then no report is sent.
P319E Mains Failure Report Delay -
Value 0-9999 Seconds (Default = 600)
SETTING DIALER TEST REPORT PARAMETERS
This option sets the days of the week and the time when an automatic test report is sent to a central monitoring
station. PLEASE NOTE: If daylight saving adjustments are set (P408-P413) do not set the value at P402 to be a
value between 1-3 am otherwise unwanted results will occur at the start & finish of daylight saving.
Also, if a
Domestic or Voice mode alarm is initiated but not reset or kissed off, when the test time comes around the
dialer will attempt to report the event/s again. To prevent this from happening, turn off ALL days at P404E.
P402E Automatic Test Report Hour/Minute -
Value 0-2359
P404E Automatic Test Report Day/s of Week -
Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
UPLOAD/DOWNLOAD SITE CODE NUMBER
The upload/download site code number must be entered if the panel is set for auto-answer as this provides a security
access level to the panel. The number can be up to 8 characters in length. Valid characters for this number are 0-9,
B-F (refer to the chart on page 35).
P505E Site Code Number -
8 characters