Page 15
THIS OPTION ON OTHERWISE DAMAGE MAY OCCUR TO THE OUTPUT CONCERNED.
Option 6
“Control” button & DTMF Remote Control can operate output -
The “Control’ button on the
PW-8 keypad can be used to turn outputs on or off. Also, if the optional 90 second voice board is
fitted, the outputs can be turned On or Off remotely via a Touchtone (DTMF) phone. For this to
happen this option must be turned on for the output/s concerned. To turn an output on locally at the
keypad the operator simply presses the “Control’ button at which time the “System” & “Program”
LED’s will illuminate to indicate that the Control mode is active. If any controllable outputs are
currently on, the relevant green led (LEDS 1-8) will be on. The operator can now press a button
relating to the output/s they wish to control e.g. pressing the “1” button will turn output 1 on or off,
The “2” button for output 2 etc. When an output state is changed the LED will indicate the change of
state. When finished the operator then presses the “Enter” button to cancel the Control mode and
return to normal. To operate the output/s via a telephone please refer to the instructions supplied
with the voice board.
Option 7
Flash 24 hour alarm
- If a 24 hour zone activates the alarm this option will cause the output to
flash at a rate equal to the value set for the pulse timer (P221E-P228E).
Option 8
Day Zones (CHIME) Linked to Pulse Timer
- Day Zones programmed to this output will pulse at
the pulse timer rate (P221E -P228E) for the duration of the day zone to output timer (P211E-P218E)
P32E - P38E
As per P31E above for Outputs 2-8
PROGRAMMING OUTPUT OPTIONS cont.
OUTPUT OPTIONS B - P41E - P48E
In this block of addresses P41E relates to output #1, P42E relates to output #2 etc
P41E 1E
Pendant Panic to Output - Default
on (P43E-48E = OFF)
2E
Keypad Panic to Output - Default
on (P43E-48E = OFF)
3E
Keypad Fire to Output - Default
off
4E
Keypad Medical to Output - Default
off
5E
Cabinet Tamper to Output- Default
on (P43E-48E = OFF)
6E
Duress Alarm to Output - Default
off
7E
Mains Fail to Output - Default
off
8E
Battery Low to Output - Default
off
Option 1
Pendant Panic to Output
- This option is used to map the operation of the Radio Pendant panic
button to an output i.e. when the Radio Panic button is pressed any output with this option enabled
will turn on.
Option 2
Keypad Panic to Output
- This option is used to map the Keypad Panic Button, or the 2 button
Panic function to an output. Keypad Panics are generated when a user presses the Panic Button or
buttons
1 & 3 Simultaneously
at the keypad.
Option 3
Keypad Fire to Output
- This option is used to map the manual Keypad Fire alarm function to an
output. The keypad Fire alarm is generated when a user presses buttons
4 & 6 Simultaneously
at
the keypad.
Option 4
Keypad Medical to Output
- This option is used to map the manual Keypad Medical alarm
function to an output. The keypad Medical alarm is generated when a user presses buttons
7 & 9
Simultaneously
at the keypad.
Option 5
Cabinet Tamper to Output
- This option is used to map activations of the common Tamper Input
to an output. This common tamper input is normally used to STAY the panel cabinet and satellite
tamper switches.
Options B O/P 1
1 2 - - 5 - - -