Page 14
USER CODE OPTIONS
USER CODE PERMISSIONS (Code Options)
-
P21E-P30E
Option 1 - Code has Area A permissions
Option 2 - Code has Area B permissions
Option 3 - Code can Arm Area
Option 4 - Code can Disarm Area
Option 5 - Code can turn STAY on
Option 6 - Code can turn STAY off
Option 7 - Code can Program their own code
Option 8 - Code can Program Other Codes
NOTE: Options 3,4, 5 & 6 are used in conjunction with options 1 & 2 whereby options 3,4,5 & 6 determine
the functions and options 1 & 2 determine the area of operation. If option 8 is on for the user, that user can
change the telephone numbers and change the Real Time Clock.
INSTALLER CODE
-
P11E
This code is used to enter full Installer Program mode (Program LED flashing).
The default installer code is 000000. To change this code enter your new
installer code at the P11E address. The new code will be flashed back to you
automatically. The Program code may vary from 3-6 digits in length.
PROGRAMMING OUTPUT OPTIONS
NOTE: With all output programming options we refer to outputs 1-8.
Only outputs 1-2 are available as standard, with outputs 3-8 requiring
the connection of the optional 4 way output expander unit that
connects to the keypad buss ( the output expander provides 4
change-over relay contacts).
OUTPUT OPTIONS A- P31E-P38E
This block of addresses (P31E - P38E) are used to map output
modifiers to each of the 8 outputs available on the PW-8.
P31E
1E
Invert output - Default
off (P34E =on)
2E
Flash output - Default
off
3E
Single pulse to output - Default
off
4E
Lockout output once reset - Default
off
5E
Siren Driver to output - Default
off
6E
“Control” button & DTMF Remote Control can operate output - Default
off
7E
Output flashes on a 24 hour zone alarm - Default
off
8E
Day zones (CHIME) linked to pulse timer - Default
off
Option 1
Invert Output
- This option is used to invert the normal state of the output. The PW-8 uses open
collector type transistor switches and the default state of all outputs is off or high. When in alarm the
transistor switch is turned on and the output is switched low. The invert option reverses this function.
Option 2
Flash Output
- This option causes the output to turn on and off at a rate set by the pulse timer for this
output (P221E -P228E) when in alarm and is normally used to flash a lamp during an activation.
Option 3
Single Pulse to Output
- This option, when applied, produces a single pulse at the output during an
alarm (the pulse time is the value programmed at the output pulse timer address, P221E-P228E).
Option 4
Lockout Once Reset
- This option is used to limit the output to one operation per arming period.
Option 5
Siren Driver to Output -
This option causes the output to be a modulated output designed to drive 8
ohm 10 watt horn speakers directly. Outputs 1 & 2 can have the siren driver feature. A different tone is
generated at output 1 to that at outputs 2.
NOTE: DO NOT CONNECT A HORN SPEAKER TO OUTPUT 1 or 2 WITHOUT FIRST TURNING
User 1 Options
1
2 3 4 5 6 7 8
Installer Code
000000
Options A O/P 1
- - - - - - - -