Page 22
you must turn LED#1 Off and LED#5 On. To use Type 4 mode for zones 1 & 5 you must turn
LED#1 On and LED#5 On. The same applies to the other zone inputs. Refer to the table on
Page 4 for more details.
PROGRAMMING ZONE OPTIONS
PROGRAMMING ZONE OPTIONS
–
P129E
,
P131E-P150E
This block of addresses (P129E - P150E) are used to select the desired functions for Zones 1-8
P131E Partition “A” Zones
Zones 1-8. (Default =
All 8 zones
)
This option allows programming of which zones will be assigned to Partition A. If a zone is in Both A & B then it
becomes common to both Areas.
P132E Partition “B” Zones
Zones 1-8. (Default = No zones)
This option allows programming of which zones will be assigned to Partition B. If a zone is in Both A & B then it
becomes common to both Areas.
P133E Zone is NC or NO
Zones 1-8. (Default =Led Off, All Zones NC, Normally Closed)
By turning the LED on for zone 1 at this address, the panel is now looking for a Normally Open (NO) contact on
the zone (4K7).
P134E Radio Zone Input
Zones 1-8. (Default = No zones)
This option allows programming of which zones will be radio zones. If a zone is a radio zone, the panel ignores
the state of the hardwired input for that zone). If the zone input has been set to tamper monitoring , the tampers
are still active even if zones are set for Radio operation.
P135E Manually BYPASSED Zone
Zones 1-8. (Default =
All 8 zones
)
This option allows programming of which zones can be manually BYPASSED prior to Arming. If a zone has this
option turned off, then that zone cannot be BYPASSED manually). Zones are BYPASSED during the disarm state
and normal zones which are BYPASSED become re-included once the alarm has been set then unset. 24 hour
zones, however remain BYPASSED until manually re-included again. Every time the alarm is set or unset with
zones BYPASSED the keypad will respond with a long beep instead of the normal 3 short beeps to indicate that
excludes are present. When excluding zones, the READY\EXCL & PROGRAM LED’s are on to indicate that you
have entered BYPASS mode. After BYPASSING zones the READY\BYP led will flash when all zones are sealed
to indicate that zones are BYPASSED
P136E Auto-BYPASSED Zone
Zones 1-8. (Default = No zones)
This option allows programming of which zones can be automatically BYPASSED at the end of the exit delay if
unsealed at that time. If a zone has this option turned off, then that zone will not auto-BYPASSED and will go into
alarm if not sealed.
P137E Follow/Handover Zone
Zones 1-8. (Default =
only zone 2 =on
)
This option allows programming of which zones will be handover zones. If a zone is a handover zone then it’s
entry delay time will apply provided a non-handover zone is triggered before the handover zone. If no other entry
delays are active when the handover zone is triggered, the zone will activate immediately.
P138E Two Trigger Zone
Zones 1-8. (Default = No zones)
This option allows programming of which zones will require two triggers before they activate. To cause an
activation a two trigger zone must alarm twice within the 2 trigger time period, P229E, or 2 two trigger zones can
alarm once each within the two trigger time period before the alarm is generated. If a two trigger zone is unsealed
and remains unsealed for a period longer than the two trigger time period, an alarm will also be generated.
P139E Stay Mode Zone
Zones 1-8. (Default = all
Zone 1-8
)
- - - - - - - -
EOL & Doubling