Page 11
KEYPAD TAMPER OPTION SETTING
Switch marked D used to Enable and Disable the Keypad Tamper option:
LED KEYPAD FUNCTIONS
The PW-8 LED Keypad consists of; an 18 button, backlit silicone rubber keypad, 14 LED ICON indicators and an
internal piezo buzzer housed in a modern white plastic housing. The plastic housing has a hinged front lid to
cover and protect the rubber buttons when not in use. All the electronics are contained on a single circuit board
inside the housing.
BUTTONS
The 18 silicone rubber buttons are used for the following functions.
In normal operating mode the numeric keys are used for entering Access Codes. In Program Mode the numeric
keys are used for entering options & new values.
The buttons with text labels are used as function buttons and select the options indicated by the text and
normally precede other button presses, e.g. to enter Bypass Mode press <
BYPASS
> and the numeric key
corresponding to the zone number you wish to be bypassed.
The
PROGRAM
Key is used to prefix option selections in the program modes e.g.<
PROGRAM
> 4 <
ENTER
>
selects User Code 4. The
PROGRAM
key is also used prior to a Master Code to enter user program mode from
normal operating mode.
The
ENTER
Key is used to enter access or program codes. It is normally used at the end of a button
sequence.
The
CONTROL
button, if enabled, is used to isolate day zone audible alarms if temporarily not required and/or
to directly control outputs if programmed.
ICON LED INDICATORS
The ICON LED indicators are used to display system conditions including Zone status, Battery state, Tamper
etc. Please refer to the LED table on page 7 for a full explanation of the conditional displays.
INSTALLING FW-RCV/RX-40 RADIO RECEIVERS
The PW8 is fully high level compatible with the new FW-RCV/RX-40 radio receivers. The addition of this
receiver will add wireless capability to your system in the form or wireless PIR detectors, Wireless Radiokey
transmitters and wireless reed switch transmitters. The RX receiver connects to the same communications port
as the keypads and can be installed , either inside the cabinet, or if preferred, may be installed at a remote
location. The RCEIVERS are available in 3 frequencies, 915MHz ,433 MHz or 868 MHz.
The RX receivers requires 4 cores and can successfully be run in 0.2mm unscreened cable over a distance of
up to 100metres. The RX has 12v connections labeled
POS and NEG
which are wired to the 12v supply and
CLK and DATA terminals for connection to the communications bus.
The green LED fitted to the RX receivers will indicate when the unit is in "Learn" mode (Flashing - see P601E)
or when it is receiving an actual radio transmission (On Steady)
D C B A
D C B A
TAMPER DISABLE