Page 31
P178E
Keypads with the Medical Buttons 7&9 or B&A Enabled -
Option keypad 1-8
(Default = None)
MEDICAL ALARM TO KEYPAD BUZZER
The two button medical function at the keypads (P178E) can
be audible or silent at the keypads. If a silent medical alarm
is required the option must be turned off at this address.
For an audible Medical Beep at the keypad/s turn this option on.
P179E
Medical Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = None)
STAY BUTTON CAN DISARM STAY MODE
The Alarm panel can be set up so that the “Stay” button at the keypad can be a single press to arm
Stay Mode. During the Stay Armed state the “Stay” button can also be used to Disarm Stay Mode
with a single press provided the keypad concerned has this option turned on. If you do not want
single button disarming of STAY mode at any keypads then ensure this option is off for the keypad/s
concerned.
Also, after Stay Mode has been armed, if the “Enter” button is pressed, all exit & entry
delays will be removed making the whole alarm instant. If the “Enter” button is not pressed then all
exit and entry delays will apply.
P180E
Stay Button can Disarm Stay Mode -
Option keypad 1-8
(Default =
All
)
MISCELLANEOUS PANEL OPTIONS # 1
This address (P169E) is used to select the first set of optional panel functions.
P169E 1E
Turn Off keypad LEDS at the end of exit time - Default off
2E
Keypad Panic Button delayed or instant - Default off
3E
Installer Code has direct access to Program Mode - Default
on
Option 1
Turn off keypad LEDS at end of exit time
- If this option is off (LED 1 Off) then the keypad LEDS
remain working at all times. If it is on (LED 1 On), the keypad LEDS will automatically turn off at the
end of the exit delay time (NOTE: the backlight LED’s on an LED keypad will remain on). The LEDS
will turn on again if the alarm is unset, an alarm occurs or any button on the keypad is pressed.
Option 2
Keypad Panic Button delayed or instant
- If this option is off (LED 2 Off) any press of the “Panic”
button on the LED keypads will result in an immediate panic alarm. If it is turned on (LED 2 On) there
will now be a 2 second delay on the panic button. The button must be held down continuously for 2
seconds to create a panic alarm.
Option 3
Installer Code has direct access to Program Mode -
If this option is off (LED 3 Off) the installer
code cannot gain direct access to installation program mode. Access to installation program mode in
this case must be via Client program Mode first (the owner must give authorization to the installer). If
the option is on (LED 3 On) then the installer code will allow direct access to Installation program
mode provided no areas are armed or in STAY mode.
Medical Combo
- - - - - - - -
Medic Beep KP
- - - - - - - -
Stay Can Disarm
1 - - 4 - - - -