Page 24
during the disarmed state and is accumulative, which means that if a zone does not trip at least once during a
disarm period the inactivity timer is not reset for that zone and will continue with the balance of the time period left
when the panel is next disarmed. The timer for each zone is reset every time a zone unseals.
PROGRAMMING ZONE INACTIVITY TIMER
P240E Inactivity Timer
- 0-255 Hours.
Default =120 Hours
PROGRAMMING ENTRY DELAYS
P301E
Zone 1 Entry Delay Time -
0-9999 Seconds (Default =
20 Sec
)
P302E
Zone 2 Entry Delay Time -
0-9999 Seconds (Default =
20 Sec
)
P303E
Zone 3 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P304E
Zone 4 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P305E
Zone 5 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P306E
Zone 6 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P307E
Zone 7 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
P308E
Zone 8 Entry Delay Time -
0-9999 Seconds (Default = 0 Sec)
PROGRAMMING EXIT DELAYS
P219E
Partition “A” Exit Delay Time -
0-255 Seconds (Default =
60 Sec
)
P220E
Partition “B” Exit Delay Time -
0-255 Seconds (Default =
60 Sec
)
PROGRAMMING TWO TRIGGER TIMER
P229E
Two Trigger Timer -
0-255 Seconds (Default =
60
Sec)
DAY MODE TO KEYPAD BUZZER TIMER
These addresses can be programmed to have a value from 0 to 99 but the value is in 1/10 of a
second increments. This means the default of 20 at addresses P209E & P210E is equal to 2
seconds. This gives a much greater control on the duration of the day zone beep to the keypad.
P209E Area “A” Day Mode to Keypad Buzzer Timer -
0-99 (Default = 20 1/10th sec)
P210E Area “B” Day Mode to Keypad Buzzer Timer -
0-99 (Default = 20 1/10th sec)
Inactivity Timer
120
Zone 1Entry De-
20
Area A Exit Delay
60
Two Trigger Timer
60