Option 1 Report Keypad Panic Alarms - If the single button
“Panic”
or the 2 button
“1&3”
Panic alarm features
are enabled then turning this on option allows the Panic Alarm to be sent via the dialer to a monitoring
station.
Option 2 Report Keypad Fire Alarm - If the 2 button
“4&6”
Fire alarm feature is enabled then turning this option
on allows the Fire Alarm to be sent via the dialer to a monitoring station.
Option 3 Report Keypad Fire Alarm - If the 2 button
“4&6”
Fire alarm feature is enabled then turning this option
on allows the Fire Alarm to be sent via the dialer to a monitoring station.
DIALER REPORTING OPTIONS “C”
This address (P188E) is used to enable or disable various alarm reports to the Dialer.
P188E 1E
Report Arm/Disarm - Default on
2E
Report Stay Mode Arm/Disarm - Default on
3E
Report Disarm only after an Activation - Default off
4E
Report Stay Mode Disarm only after an Activation - Default off
5E
Report
24 Hour Alarms when set to Domestic/Voice mode - Default off
6E
Send Arm immediately - Default off
7E
Send Zone alarms in Stay Mode - Default off
8E
Spare - Default off
Option 1
Report Arm/Disarm -
If this option is on then all Arm/Disarm signals will be reported to a central
Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 2
Report Stay Mode Arm/Disarm -
If this option is on then all Stay Mode Arm/Disarm signals will be
reported to a central Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3
Send unset after activation
- If this option is on, the panel will not normally send an Arm/Disarm signal
to the monitoring company, however, if a zone alarm occurs then the panel will send a Disarm following
the disarming of the panel to show it has been turned off by a valid user.
Option 4
Send Stay Mode unset after activation -
If this option is on, the panel will not normally send a Stay
Mode Arm/Disarm signal to the monitoring company, however, if a zone alarm occurs then the panel will
send a Disarm and group bypass restore following the disarming of the panel to show it has been turned
off by a valid user.
Option 5
Report
24 Hour Alarms when set to Domestic/Voice mode -
When the panel is set to send alarms via
domestic or voice mode, NO alarms will normally be sent for 24 hour zones. If 24 hour alarms are
required to be reported in Domestic/Voice mode then this option must be turned on.
Option 6
Send Arm immediately
- If this option is on, the arm report is sent immediately the panel is armed. If
the option is turned off, the arm signal will be sent at the expiry of the exit delay timer.
Option 7
Send Zone alarms in Stay Mode
- If this option is on, any Stay Mode zone alarms will be reported via
the dialer. If it is off, no Stay Mode zone alarms will be transmitted via the dialer.
1 2 3 - - - - -
Dialer Report 2
Dialer Report 3
1 2 - - - - - -