Page 31
FIRE ALARM TO KEYPAD BUZZER
The two button fire function at the keypads (P176E) can be audible or silent at the keypads. If a silent
fire alarm is required the option must be turned off at this address. For an audible Panic Beep at the
keypad/s turn this option on.
P177E
Fire Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = None)
KEYPADS MEDICAL (7&9) OR (B&A) ENABLED
By pressing the buttons 7&9 or B&A simultaneously it is possible to create a Medical alarm report to
the dialer. If you want this Medical function enabled at any of the keypads you must enable the
operation at this address.
P178E
Keypads with the Medical Buttons 7&9 or B&A Enabled -
Option keypad 1-8
(Default = None)
MEDICAL ALARM TO KEYPAD BUZZER
The two button medical function at the keypads (P178E) can be audible or silent at the keypads. If a
silent medical alarm is required the option must be turned off at this address. For an audible Medical
Beep at the keypad/s turn this option on.
P179E
Medical Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = None)
STAY BUTTON CAN DISARM STAY MODE
The Alarm panel can be set up so that the “Stay” button at the keypad can be a single press to arm
Stay Mode. During the Stay Armed state the “Stay” button can also be used to Disarm Stay Mode
with a single press provided the keypad concerned has this option turned on. If you do not want
single button disarming of STAY mode at any keypads then ensure this option is off for the keypad/s
concerned.
Also, after Stay Mode has been armed, if the “Enter” button is pressed, all exit & entry
delays will be removed making the whole alarm instant. If the “Enter” button is not pressed then all
exit and entry delays will apply.
P180E
Stay Button can Disarm Stay Mode -
Option keypad 1-8
(Default = 1 & 4)
Fire Beep KP
- - - - - - - -
Medical Combo
- - - - - - - -
Medic Beep KP
- - - - - - - -
Stay Can Disarm
1 - - 4 - - - -