Page 25
DAY MODE TO KEYPAD BUZZER TIMER
These addresses can be programmed to have a value from 0 to 99 but the value is in 1/10 of a
second increments. This means the default of 20 at addresses P209E & P210E is equal to 2
seconds. This gives a much greater control on the duration of the day zone beep to the keypad.
P209E Area “A” Day Mode to Keypad Buzzer Timer -
0-99 (Default = 20 1/10th sec)
P210E Area “B” Day Mode to Keypad Buzzer Timer -
0-99 (Default = 20 1/10th sec)
OUTPUT TIMING OPTIONS
OUTPUT RESET TIME-P311E-P318E (0-9999 Seconds)
The output reset time is how long an output will stay on following an alarm condition. A value of “0”
means the output will latch until reset by a valid user code.
P311E Output 1 Alarm Reset Time -
(Default = 300 Sec)
P312E Output 2 Alarm Reset Time -
(Default = 300 Sec)
P313E Output 3 Alarm Reset Time -
(Default = 0 Sec)
P314E Output 4 Alarm Reset Time -
(Default = 0 Sec)
P315E Output 5 Alarm Reset Time -
(Default = 0 Sec)
P316E Output 6 Alarm Reset Time -
(Default = 0 Sec)
P317E Output 7 Alarm Reset Time -
(Default = 0 Sec)
P318E Output 8 Alarm Reset Time -
(Default = 0 Sec)
OUTPUT DELAY ON TIME-P201E-P208E (0-99 Seconds)
The output delay ON time is how long an output will be delayed before turning on following an alarm
condition.
P201E Output 1 Delay On Time -
(Default = 0 Sec)
P202E Output 2 Delay On Time -
(Default = 0 Sec)
P203E Output 3 Delay On Time -
(Default = 0 Sec)
P204E Output 4 Delay On Time -
(Default = 0 Sec)
P205E Output 5 Delay On Time -
(Default = 0 Sec)
P206E Output 6 Delay On Time -
(Default = 0 Sec)
P207E Output 7 Delay On Time -
(Default = 0 Sec)
P208E Output 8 Delay On Time -
(Default = 0 Sec)
OUTPUT DAY MODE TIME-P211E-P218E (0-99 1/10th Second)
The output day mode timer is how long an output will turn on following a day zone unsealing. The
Day Mode Timer is in 1/10th Sec intervals e.g. 20=2 Seconds
P211E Output 1 Day Mode Time -
(Default = 20)
P212E Output 2 Day Mode Time -
(Default = 20)
P213E Output 3 Day Mode Time -
(Default = 20)
P214E Output 4 Day Mode Time -
(Default = 20)
P215E Output 5 Day Mode Time -
(Default = 20)
P216E Output 6 Day Mode Time -
(Default = 20)
P217E Output 7 Day Mode Time -
(Default = 20)
P218E Output 8 Day Mode Time -
(Default = 20)
OUTPUT PULSE TIMER-P221E-P228E (0-99 1/10th Second)
The output pulse timer is how long an output will turn on when the pulse timer is used. The Pulse
Timer is in 1/10th Sec intervals e.g. 20=2 Seconds
P221E Output 1 Pulse Timer -
(Default = 20)
P222E Output 2 Pulse Timer -
(Default = 20)
AreaA Chime time
20
O/P 1 Reset Time
300
O/P 1 Delay Time
0
O/P 1 Chime Time
20
Summary of Contents for PowerWave-4