Page 30
KEYPADS WITH PANIC BUTTON ENABLED
The panic button on all keypads can be set for delayed or instant operation. If you do not want the
Panic function enabled at any of the keypads you can disable the operation at this address. This
option may be useful where a keypad has to be installed in a public area.
P173E
Keypads with the Panic Button Enabled -
Option keypad 1-8
(Default = All keypads 1-8)
KEYPADS PANIC (1&3)OR (CHIME&CONTROL) ENABLED
An alternative Panic function to the dedicated panic button is to press the keypad buttons 1&3
simultaneously. If you do not want this Panic function enabled at any of the keypads you can disable
the operation at this address. This option may be useful where a keypad has to be installed in a
public area.
P174E
Keypads with the Panic Buttons 1&3 or CHIME&CONTROL Enabled -
Option keypad 1-8
(Default = None)
KEYPAD & RADIO PANIC ALARM TO KEYPAD BUZZER
The two Keypad panic functions (P173E or P174E) plus the Radio Panic Alarms can be audible or
silent at the keypads. If a silent panic is required the option must be turned off at this address. For an
audible Panic Beep at the keypad/s turn this option on.
P175E
Keypad & Radio Panic Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = All keypads 1-8)
KEYPADS FIRE (4&6) OR (CHIME&B) ENABLED
By pressing the buttons 4&6 or CHIME&B simultaneously it is possible to create a Fire alarm report
to the dialer. If you want this Fire function enabled at any of the keypads you must enable the
operation at this address.
P176E
Keypads with the Panic Buttons 4&6 or CHIME&B Enabled -
Option keypad 1-8
(Default = None)
KP With Panic
1 2 3 4 5 6 7 8
Panic Combo
1 2 3 4 - - - -
Panic Beep KP
1 2 3 4 5 6 7 8
Fire Combo
- - - - - - - -
Summary of Contents for PowerWave-4