Page 16
Option 3
Keypad Fire to Output
- This option is used to map the manual Keypad Fire alarm function to an
output. The keypad Fire alarm is generated when a user presses buttons
4 & 6 Simultaneously
at
the keypad.
Option 4
Keypad Medical to Output
- This option is used to map the manual Keypad Medical alarm
function to an output. The keypad Medical alarm is generated when a user presses buttons
7 & 9
Simultaneously
at the keypad.
Option 5
Cabinet Tamper to Output
- This option is used to map activations of the common Tamper Input
to an output. This common tamper input is normally used to STAY the panel cabinet and satellite
tamper switches.
Option 6
Duress Alarm to Output
- This option will map the Duress Function to an output. Programming of
the Duress Digit is at address P230E.
Option 7
Mails Fail To Output
- A mains failure will be indicated at this output when option 7 is enabled at
this address. The Alarm Reset Timer must be set to “0”
when this option is used.
Option 8
Low Battery
- A battery Low condition will be indicated at this output when option 8 is enabled at
this address. The alarm reset timer must be set to “0” when this option is used.
P42E - P48E
As per P41E above for Outputs 2-8
MAPPING ZONE ALARMS TO OUTPUTS
ZONE ALARM MAPPING TO OUTPUTS - P51E - P58E
When a zone is in alarm (during the ARMED state only) this block of addresses allows individual
zones to be mapped to selected outputs. The default setting is
that zones 1-4 will turn on all outputs 1-8 when in alarm.
P51E
Zone Alarms to Output #1. Options=Zones 1-4 (Default=1-4)
P52E
Zone Alarms to Output #2. Options=Zones 1-4 (Default=1-4)
P53E
Zone Alarms to Output #3. Options=Zones 1-4 (Default=0)
P54E
Zone Alarms to Output #4. Options=Zones 1-4 (Default=0)
P55E
Zone Alarms to Output #5. Options=Zones 1-4 (Default=0)
P56E
Zone Alarms to Output #6. Options=Zones 1-4 (Default=0)
P57E
Zone Alarms to Output #7. Options=Zones 1-4 (Default=0)
P58E
Zone Alarms to Output #8. Options=Zones 1-4 (Default=0)
MAPPING STAY ZONE ALARMS TO OUTPUTS
STAY ZONE ALARM MAPPING TO OUTPUTS - P61E - P68E
When a Stay Mode zone is in alarm (during the STAY state only) this block of addresses allows
individual zones to be mapped to selected outputs. The default setting is that zones 1-4 will turn on
output 2 only when a STAY mode alarm occurs.
P61E
Stay Mode Zone Alarms to Output #1. Options=Zones 1-4 (Default=1-8)
P62E
Stay Mode Zone Alarms to Output #2. Options=Zones 1-4 (Default=1-8)
P63E
Stay Mode Zone Alarms to Output #3. Options=Zones 1-4 (Default=None)
P64E
Stay Mode Zone Alarms to Output #4. Options=Zones 1-4 (Default=None)
P65E
Stay Mode Zone Alarms to Output #5. Options=Zones 1-4 (Default=None)
P66E
Stay Mode Zone Alarms to Output #6. Options=Zones 1-4 (Default=None)
P67E
Stay Mode Zone Alarms to Output #7. Options=Zones 1-4 (Default=None)
P68E
Stay Mode Zone Alarms to Output #8. Options=Zones 1-4 (Default=None)
1 2 3 4 5 6 7 8
Alarm To O/P 1
Stay Alarm O/P 1
1 2 3 4 5 6 7 8