Page 17
MAPPING 24 HOUR ZONE ALARMS TO OUTPUT
24 HOUR ZONE ALARM MAPPING TO OUTPUTS - P71E - P7
8E
When a 24 Hour zone is in alarm this block of addresses allows individual zones to be mapped to
selected outputs. The default setting is that zones 1-4 will turn on output 2 only when a 24 Hour
alarm occurs.
P71E
24 Hour Zone Alarms to Output #1. Options=Zones 1-4 (Default=1-4)
P72E
24 Hour Zone Alarms to Output #2. Options=Zones 1-4 (Default=1-4)
P73E
24 Hour Zone Alarms to Output #3. Options=Zones 1-4 (Default=None)
P74E
24 Hour Zone Alarms to Output #4. Options=Zones 1-4 (Default=None)
P75E
24 Hour Zone Alarms to Output #5. Options=Zo nes 1-4 (Default=None)
P76E
24 Hour Zone Alarms to Output #6. Options=Zones 1-4 (Default=None)
P77E
24 Hour Zone Alarms to Output #7. Options=Zones 1-4 (Default=None)
P78E
24 Hour Zone Alarms to Output #8. Options=Zones 1-4 (Default=None)
MAPPING DAY ZONES TO OUTPUTS
DAY ZONES TO OUTPUTS - P81E - P88E
When a Day zone is unsealed this block of addresses allows individual zones to be mapped to
selected outputs. The default setting is that no Day zones are mapped to any of the 8 outputs.
P81E
Day Zones to Output #1. Options=Zones 1-4 (Default=None)
P82E
Day Zones to Output #2. Options=Zones 1-4 (Default=None)
P83E
Day Zones to Output #3. Options=Zones 1-4 (Default=None)
P84E
Day Zones to Output #4. Options=Zones 1-4 (Default=None)
P85E
Day Zones to Output #5. Options=Zones 1-4 (Default=None)
P86E
Day Zones to Output #6. Options=Zones 1-4 (Default=None)
P87E
Day Zones to Output #7. Options=Zones 1-4 (Default=None)
P88E
Day Zones to Output #8. Options=Zones 1-4 (Default=None)
MAPPING ZONE TAMPERS TO OUTPUTS
ZONE TAMPER MAPPING TO OUTPUTS - P91E - P98E
When a zone input is set for Dual-End-of-Line (P130E) the short & open circuit tampers are
automatically enabled for that zone input. This option allows the zone tamper alarms to be mapped
through to individual outputs.
Led
1-4 is a short on the Zone 1-4 and a Led 5-8 is an open loop in
Zone 1-4.
P91E
Zone Tamper to Output #1. Options= Zone Tampers 1-8 (Default=1-8)
P92E
Zone Tamper to Output #2. Options= Zone Tampers 1-8 (Default=1-8)
P93E
Zone Tamper to Output #3. Options= Zone Tampers 1-8 (Default=1-8)
P94E
Zone Tamper to Output #4. Options= Zone Tampers 1-8 (Default=None)
P95E
Zone Tamper to Output #5. Options= Zone Tampers 1-8 (Default=None)
P96E
Zone Tamper to Output #6. Options= Zone Tampers 1-8 (Default=None)
P97E
Zone Tamper to Output #7. Options= Zone Tampers 1-8 (Default=None)
P98E
Zone Tamper to Output #8. Options= Zone Tampers 1-8 (Default=None)
1 2 3 4 5 6 7 8
24 Alarm O/P 1
Chime To O/P 1
- - - - - - - -
1 2 3 4 5 6 7 8
Tamper To O/P 1
Summary of Contents for PowerWave-4