P412E Daylight Saving End Month -
Value 1-12 - Default = 3
P413E Daylight Saving End Hour -
Value 0-23 - Default = 3
When setting up a panel for the first time using daylight saving, you must ascertain whether daylight saving is
currently ACTIVE. If it is you must enter in P414E then 1E to tell the panel that daylight saving is ON to sync the
panel to daylight saving mode. If this is not done then when daylight saving finishes the panel will not adjust the
clock.
P414E Daylight Saving is Active (If LED #1 is On, Daylight Saving is currently active)
RESTORE FACTORY DEFAULTS
This address (P620E) is used to return the panel back to factory default settings.
P620E Restore Factory Defaults
RESTORING SELECTED DEFAULTS
P621E Restore User Codes to Default only.
P622E Restore all Program Addresses from 20-199 to Default
P623E Restore all Program Addresses from 200-399 to Default
P624E Restore all Program Addresses from 500-599 to Default
P625E Restore all Radio & Pendant codes to Default
CLEAR ALARM MEMORY BUFFER
This address (P626E) is used to clear the panels alarm memory buffer.
P626E
Clear Alarm Memory Buffer
WALK TEST MODE
This address (P627E) is used to enable walk-test mode while in installer program mode. By pressing
P627E at the keypad, the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is
active. By walking past all of the detectors connected to the system and activating them, the associated
zone light will latch up at the keypad to allow verification that all zones are working properly. By pressing
the “Program” or “Enter” buttons, walk-test mode can be terminated and normal programming resumed.
DLS Status
1
Reset All
Done
Reset Addr 21-199
Done
Clear Mem Buffer
Done