Page 36
DIALER PROGRAMMING SECTION
The Dialer section of this alarm panel has many different programmable options. Some of these options require
special function keys to select or program the options when entering telephone numbers or 4+2 codes. These special
function keys and their corresponding keypad LED indications are listed in the following table
.
LED KEYPAD LED KEYPAD LCD KEYPAD 4+2 FUNCTION TELEPHONE NUMBER
BUTTON INDICATION BUTTON SPECIAL FUNCTION
“0”
ARMED A 0 “0 or A” N/A
“PANIC”
READY/BYP CONTROL & 2 “B” “#”
“MEMORY”
SYSTEM CONTROL & 3 “C” “*”
“CONTROL”
TROUBLE CONTROL & 4 “D” “2.5 sec Pause”
“ARM”
READY/BYP CONTROL & 5 “E” “Wait for 2nd Dial-tone”
SYSTEM
“STAY”
READY/BYP CONTROL & 6 “F” “5 sec Pause”
TROUBLE
DIALER PROGRAMMING OPTIONS
This address (P185E) is used to turn the dialer on and select other dialer related options.
P185E 1E
Dialer is Enabled - Default ON
2E
Fax Defeat - Default ON
3E
Disable Telephone Line Monitoring - Default off
4E
DTMF or Pulse Dialing - Default off (NOTE: Options 4 & 5 must be OFF for DTMF Dial)
5E
DTMF or Reverse Pulse Dialing - Default off (NOTE: Options 4 & 5 must be OFF for DTMF Dial)
6E
Spare - Default off
7E
Auto-detect Modem - Default on
8E
Bell 103 or V21 - Default off
Option 1
Dialer is Enabled
- If this option is turned off the dialer will be disabled. The option must be on to allow
the dialer to make calls.
Option 2
Fax Defeat -
The panel can answer an in-coming call in two ways. The first is to set the auto-answer
ring count to a convenient number (P249E) and let the phone ring until this number is reached at which
time the panel will answer the call. The second method is to use fax defeat which entails calling the
panel and letting it ring no more than 4 times, hanging up, then ringing back within 45 seconds. The
panel will now answer the call on the first ring.
Option 3
Disable Telephone line Monitoring -
If the panel is connected to a poor telephone line and the line
failure alarm is appearing regularly, by turning this option on the panel will not do the line test.
Option 4
DTMF or Pulse Dial -
If this option is On then the panel will dial using Normal Pulse Dialing format (eg
the number 9 = 9 pulses)
NOTE: Options 4 & 5 must be OFF for DTMF Dial
Option 5
DTMF or Reverse Pulse Dial -
If this option is On then the panel will dial using Reverse Pulse Dialing
format (e.g. the number 9 = 1 pulse)
NOTE: Options 4 & 5 must be OFF for DTMF Dial
Option 6
Spare
Option 7
Auto-detect Modem
- If this option is on the panel will answer an in-coming call with the V21
acknowledge tone. If the modem does not respond within 5 seconds the panel will then generate the
acknowledge tones for Bell 103 format. It will repeat this cycle twice and then hang-up if no
communication with a modem is established.
Option 8
Bell 103 or V21 -
The dial up panel to PC link can be established using either Bell 103 or V21. If the
auto-detect function at option 7 does not result in the best format for your modem then you can force the
Summary of Contents for PowerWave-4