11.4.
"Conveyor Belt" Group
11.4.1.
"Conveyor Belt 0-10V" Application Program
Figure
43
The "Conveyor Belt 0-10V" application program invokes the V101 expert program.
The user can switch to this expert mode at any time to access all the settings by clicking the "Expert Mode"
button.
The values preset in application mode will be loaded directly in expert mode.
It is then impossible to return to this application program.
The user can press the "STOP" button at any time to stop the application quickly.
To restart the motor, the program needs to be reloaded.
Once the settings are complete, press the "Load Program" button to configure the motor.
11.4.1.1. Inputs/Outputs Configuration
Refer to the "I/O Connection" section.
Inputs:
•
IN1: If 0
→ Stop, if 1 → Run
•
IN2: If 0
→ motor running in reverse (CCW), if 1 → motor running forward (CW)
•
IN3: If IN3 = 1 and IN1 = 1 and IN6 = 0, application of a 150 mNm holding torque.
•
IN4: If 0
→ no action, if 1 → Quick start by short-circuiting the coils. This action takes priority over the
other commands.
•
IN5: 0-10 V control. Sets the motor acceleration and deceleration. 40,000 rpm/sec for 0 V (maximum
acceleration) and 100 rpm/sec for 10 V.
Input
connections
Output
connections