Crestron
TPMC-10
Isys
i/O
™
WiFi Touchpanel
Serial Input & Output Signal Descriptions
TOUCHPANEL
SIGNAL NAME
AND TYPE
VT Pro-e
JOIN TYPE
VT Pro-e
OBJECT DESCRIPTION
Indirect
Text Join
Border
Button
Legend
Text
Gauge
Slider
Sends text to the object's text field for
display during run time.
Serial inputs:
<
text-o1
> through
<
text-o4000
>
All serial inputs are
permanent.
To set the maximum
size of the string
(recommended), use
the optional
<
Permanent String
Size
> parameter.
Target Join
Embedded
Application
Sends a new file path and/or filename to
the TPMC-10.
If the application is not open, the TPMC-10
will open the file when the Open/Close join
for the application goes high.
If the embedded application is already
open, the new path and file name will not
take effect until the application is closed
and reopened.
If the string is not valid (i.e., the target
does not exist), the TPMC-10 will send an
error code to the control system via the
Errors/Warnings analog join for the Project
Properties. Logic should then be
programmed to handle the error or trigger
the "Open File" window.
The Target string will persist in the panel's
memory until a new string overwrites it,
i.e., the control system sends a new string
on the Target join, or the end user selects
a new target locally.
Operations Guide – DOC. 6284B
Isys i/O
™
WiFi Touchpanel: TPMC-10
•
31