The maximum continuous current from equipment under any external
load conditions shall not exceed a current limit that is suitable for the minimum
wire gauge used in interconnecting cables. The ratings on the connecting unit's
supply input should be considered to prevent overloading the wiring.
QM-RX Hookup
Ground Wire Connections
Proper grounding is required. Connect the ground from the QM-RX to earth
ground. Connect the Cresnet shield lead at the control processor to the ground
lead. The control processor chassis must also be connected to an earth ground
(building steel). Refer to the following grounding diagram.
Ground Wire Connections
NOTE:
Do not connect the shield to earth ground at the QM-RX
Operations Guide – DOC. 6333