PN 26037-00 R072208
12
ASSEMBLY
4.3 aiR TubeS
manifold lengTh
# of ShoRT
aiR TubeS
# of long
aiR TubeS
15 FT. (12” SPACING) (DRILL)
7
7
20 FT. (12” SPACING) (DRILL)
9
10
20 FT. (13 5/16” SPACING)
9
9
25 FT. (12” SPACING) (DRILL)
12
13
25 FT. (13 5/16” SPACING)
11
12
30 FT. (12” SPACING) (DRILL)
14
15
30 FT. (13 5/16” SPACING)
13
14
4.3.1 manifoldS WiTh 12” Tube Spacing
When installing the air tubes, start working from the LH side (as
looking from the combine cab) of the manifold and work to the
right. Install a short air tube first. In step 6, you will drill holes for
the long end tubes. Refer to Figure 8 during assembly.
Begin by installing a short air tube at an end hole and
•
alternate short and long air tubes the length of the
manifold.
You will drill a hole for a long air tube at each end of
•
the manifold after installing all other air tubes.
Apply the self adhesive foam seals.
1.
Remove and discard the slot and two hole cutouts
A.
from the self adhesive foam seal.
Remove the self adhesive foam seal from the back-
B.
ing and apply foam seal to manifold.
To connect the air tube, place it on one of the holes in the
2.
manifold and point the end towards the direction of the
cutterbar.
Install the U-bolt around the manifold and through the holes
3.
on the air tube weldment. Make sure the air tube seats in the
manifold hole to maintain proper tube alignment.
Secure the U-bolt with two 5/16” flange nuts. Torque to
4.
17 ft-lbs.
Repeat procedure for all air tubes, making sure to alternate
5.
long and short air tubes.
To mount the end air tubes, a 1-9/16” hole must be drilled
6.
on each end of the manifold. Drill the holes as far to the
outside of the header as possible, while still providing room
to install the air tube. Repeat the steps above to mount the
end air tubes.
4.3.2 all oTheR manifoldS
When installing the air tubes, start working from the LH side (as
looking from the combine cab) of the manifold and work to the
right. Refer to Figure 8 during assembly.
The first air tube installed will be a long air tube.
•
Alternate short and long air tubes the length of the
•
manifold.
Apply the self adhesive foam seals.
1.
Remove and discard the slot and two hole cutouts
A.
from the self adhesive foam seal.
Rem
B.
ove the self adhesive foam seal from the back-
ing and apply foam seal to manifold.
To connect the air tube, place it on one of the holes in the
2.
manifold and point the end towards the direction of the
cutterbar.
Install the U-bolt around the manifold and through the holes
3.
on the air tube weldment. Make sure the air tube seats in the
manifold hole to maintain proper tube alignment.
Secure the U-bolt with two 5/16” flange nuts. Torque to
4.
17 ft-lbs.
Repeat procedure for all air tubes, making sure to alternate
5.
long and short air tubes.
Figure 8, Drop tube assembly