34
Engineer Manual
Inspire Black 960H DVR Range
Connecting keyboard and PTZ camera
If you want to control PTZ cameras & speed domes from both the DVR and the keyboard
then both RS485 busses must be connected together.
RS485
RS485
Recommended cable is CAT-5.
Maximum cable run is recommended at 500 metres for each device.
DVR, PTZ camera & keyboard must all be set to the same protocol and baud rate.
Keyboard Setting
Set the DIP switch on the keyboard.
PTZ Camera Setting
Each PTZ camera must be set with an individual ID number.
See PTZ camera instructions for details on changing these settings.
DVR Setting
For multiple DVR configuration, you need to the set DVR ID, see page 64 for details.
The settings for the PTZ communication protocol must be set to Pelco D 2400 baud rate,
see page 71 for details of setting the DVR for PTZ use.
-
-
-
-
+
+
+
RS101R