72
FM-3 Programming Module Reference Manual
I/O Setup Group
The I/O Setup group contains four views that control input and output functions as well as
other drive functions. These views are as follows: Selector, Assignments, Input Lines and
Output Lines. These can be viewed by expanding I/O Setup by simply clicking on any one of
the setup views underneath the I/O Setup.
Assignments
External control capability is provided through the use of assignments to the sources (Drive
Inputs and Module Inputs) or the destinations (Drive Outputs and Module Outputs).
Assignments provide a mechanism for the user to define the internal and external dynamic
control structure to separate complex motion profiles. These functions directly correspond to
any input or output line on the drive or the FM-3 module. External controllers, such as a PLC
or other motion controllers, may be connected to affect or monitor the device’s operation.
The drives are equipped with five optically isolated input lines (one dedicated to a Drive
Enable function) and three optically isolated output lines. The FM-3 module has an additional
eight input and four output lines.
The drive’s input and output lines can be accessed through the removable 10-pin I/O
connector (J6), or through the 44-pin command connector (J5). The FM-3 input and output
lines are located on the front of the FM-3 module.
All inputs and outputs are configured as sourcing and are designed to operate from a +10 to
30 VDC power source. You are responsible for limiting the output current to less than 200
mA for each digital output.
Assignments View
The Assignments View not only displays information but also makes assignments regarding
the source and the destination.
Summary of Contents for FM-3
Page 2: ......
Page 14: ...xii ...
Page 16: ...2 FM 3 Programming Module Reference Manual Figure 2 FM 3 Programming Module Features ...
Page 128: ...114 FM 3 Programming Module Reference Manual ...
Page 156: ...142 FM 3 Programming Module Reference Manual ...
Page 196: ...182 FM 3 Programming Module Reference Manual ...
Page 238: ...224 FM 3 Programming Module Reference Manual ...
Page 251: ...237 Diagnostics and Troubleshooting Figure 97 Diagnostic Cable DGNE Diagram ...
Page 262: ...248 FM 3 Programming Module Reference Manual ...
Page 264: ...250 FM 3 Programming Module Reference Manual AX4 CEN CDRO ...
Page 265: ...251 Specifications Cable Diagrams ...
Page 266: ...252 FM 3 Programming Module Reference Manual SNCE XXX Cable SNCDD 001 5 Cable ...
Page 267: ...253 Specifications SNCO 003 Cable SNCI 003 Cable ...
Page 268: ...254 FM 3 Programming Module Reference Manual SNCLI 003 Cable ...
Page 272: ...258 FM 3 Programming Module Reference Manual TIA XXX Cable DDS XXX Cable ...
Page 274: ...260 FM 3 Programming Module Reference Manual CMDS XXX Cable CMMS XXX Cable ...
Page 275: ...261 Specifications CFCS XXX Cable ...
Page 276: ...262 FM 3 Programming Module Reference Manual CFCO XXX Cable ...
Page 277: ...263 Specifications CFOS XXX Cable ...
Page 278: ...264 FM 3 Programming Module Reference Manual ...
Page 286: ...272 FM 3 Programming Module Reference Manual ...
Page 290: ...276 FM 3 Programming Module Reference Manual ...
Page 291: ......