112
FM-3 Programming Module Reference Manual
An external device such as a Human Machine Interface (HMI) or PLC can be used to monitor
or edit individual FM-3 module parameters. The FM-3 module and drives use a 32-bit
Modbus RTU communications protocol.
In order to view or modify a parameter, a Modbus address must be assigned to the specific
parameter. To do this, locate the parameter you wish to read/write to or from in the variables
list in the middle of the view. Once you have found the proper parameter, click and hold the
left mouse button over the parameter. While still holding the button on your mouse, drag the
parameter into the Modbus window area on the right of the view. Now let go of the mouse
button.
A “New Assignment” dialog box will appear. This will automatically assign the next
available modbus address, or allow you to enter a different Modbus address. Once you click
on OK, then you will be able to read or write the parameter at that address.
Figure 64:
Modbus Address Assignment Box
Address ranges are as follows:
Any individual Modbus address can be deleted by highlighting the parameter you wish to
delete, and clicking on the Remove button. The address selected will be removed from the
list. If you wish to delete all of the Modbus addresses that have been created, then simply click
on the Remove All button. All of the addresses will disappear and the Modbus window will
be empty.
Some Modbus addresses have been reserved and can not be assigned:
39980-39999 and 49501-49999.
Address Range
Accessibility
Type
Data Size
4xxxx
Read/Write
Register
32 bit word
3xxxx
Read Only
Register
32 bit word
1xxxx
Read Only
Input Bits
bit
0xxxx
Read/Write
Coil
bit
Summary of Contents for FM-3
Page 2: ......
Page 14: ...xii ...
Page 16: ...2 FM 3 Programming Module Reference Manual Figure 2 FM 3 Programming Module Features ...
Page 128: ...114 FM 3 Programming Module Reference Manual ...
Page 156: ...142 FM 3 Programming Module Reference Manual ...
Page 196: ...182 FM 3 Programming Module Reference Manual ...
Page 238: ...224 FM 3 Programming Module Reference Manual ...
Page 251: ...237 Diagnostics and Troubleshooting Figure 97 Diagnostic Cable DGNE Diagram ...
Page 262: ...248 FM 3 Programming Module Reference Manual ...
Page 264: ...250 FM 3 Programming Module Reference Manual AX4 CEN CDRO ...
Page 265: ...251 Specifications Cable Diagrams ...
Page 266: ...252 FM 3 Programming Module Reference Manual SNCE XXX Cable SNCDD 001 5 Cable ...
Page 267: ...253 Specifications SNCO 003 Cable SNCI 003 Cable ...
Page 268: ...254 FM 3 Programming Module Reference Manual SNCLI 003 Cable ...
Page 272: ...258 FM 3 Programming Module Reference Manual TIA XXX Cable DDS XXX Cable ...
Page 274: ...260 FM 3 Programming Module Reference Manual CMDS XXX Cable CMMS XXX Cable ...
Page 275: ...261 Specifications CFCS XXX Cable ...
Page 276: ...262 FM 3 Programming Module Reference Manual CFCO XXX Cable ...
Page 277: ...263 Specifications CFOS XXX Cable ...
Page 278: ...264 FM 3 Programming Module Reference Manual ...
Page 286: ...272 FM 3 Programming Module Reference Manual ...
Page 290: ...276 FM 3 Programming Module Reference Manual ...
Page 291: ......