Actuator LED
Original Entry Sensor
Ready (Green)
Original Exit Sensor
Ready (Green)
Adjustment Slider for Media Thickness
Wait
10.1.5
Test 5, Lamp Test
Purpose
: To test the Lamp and associated electronics.
Description
: A message on the screen will inform whether the
Lamp
is turned ON or OFF
(Lamp power is turned ON/OFF) and whether the
Light
is ON/OFF (Light is detected or not).
The Lamp is delayed approx. 2 seconds when switched ON.
10.1.6
Test 6, Motor Test
Purpose
: To test the Stepper Motor and associated electronics.
Description:
From the menu the motor speed and the direction of rotation can be selected.
10.1.7
Test 7, Complete Hardware Test
Purpose
: To test various functions on the SUC and CBE/CBF-Boards.
10.1.8
Test 9, Camera Adjustment
See also Test 27, Camera Adjustment Wizard
Purpose
: To support CCD-Camera evaluation and adjustments.
Description
: Test 9 contains a “Software Oscilloscope” for check and adjustment of the
cameras. The following functions can be selected from the Test Program Menu.
•
Uncorrected or Corrected Light Profile
•
Red, Green, Blue, or Gray Color Channel (Selections depend on scanner model)
•
Special Detail Views for Light Profile, Scan Width, and Vertical Positioning
•
Forward / Reverse controls for the Camera Motor
•
Save screen images
•
Print screen images
•
Load saved images
The contents of Detail Views is marked on the upper overview window by red vertical lines.
The continuous lines refer to the left Detail View and the dashed lines to the right Detail
View.
10.1.9
Test 11, Stitching and Vertical Alignment
Purpose:
Performs Automatic Vertical Alignment and Horizontal Stitching.
Description
: After Test 11 has been started:
•
Insert
SM Calibration Sheet
•
Select
Vertical Alignment to align the cameras
•
Select
Horizontal Stitching to stitch the cameras
Summary of Contents for CHAMELEON 25
Page 69: ...FSG MTM 001 060511 65 Fig 3 21 OIBA Component Layout Fig 3 20 OSB Component Layout ...
Page 102: ...FSG MTM 001 060511 98 Fig 4 19 COUGAR Tx 36 CHAMELEON Tx 36 PREMIER Tx 36 Focus Signals ...
Page 106: ...FSG MTM 001 060511 102 Fig 4 20 COUGAR 25 CHAMELEON 25 Scan Width ...
Page 109: ...FSG MTM 001 060511 105 Fig 4 25 CHROMA Tx 40 CRYSTAL Tx 40 Scan Width Camera C ...
Page 118: ...FSG MTM 001 060511 114 Fig 4 32 COUGAR 25 CHAMELEON 25 CCD Centering and Vertical Positioning ...
Page 183: ...FSG MTM 001 060511 179 Fig 11 1 COUGAR 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 185: ...FSG MTM 001 060511 181 Fig 11 3 CHAMELEON 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 187: ...FSG MTM 001 060511 183 Fig 11 5 COUGAR 36 Primary Wiring WHITE SMPS WHITE LME L N WHITE ...
Page 193: ...FSG MTM 001 060511 189 Fig 11 11 MAGNUM XL 54 Primary Wiring ...
Page 194: ...FSG MTM 001 060511 190 Fig 11 12 MAGNUM XL 54 Secondary Wiring ...
Page 205: ...FSG MTM 002 060511 7 Fig 2 1 COUGAR Sx 25 and CHAMELEON Sx 25 Block Diagram ...
Page 207: ...FSG MTM 002 060511 9 Fig 2 2 CHROMA XL 42 and CRYSTAL XL 42 Block Diagram ...
Page 241: ...FSG MTM 002 060511 43 Fig 6 1 Sx 25 Primary Wiring ...
Page 242: ...FSG MTM 002 060511 44 Fig 6 2 Sx 25 Secondary Wiring ...
Page 243: ...FSG MTM 002 060511 45 Fig 6 3 XL 42 Primary Wiring ...
Page 244: ...FSG MTM 002 060511 46 Fig 6 4 XL 42 Secondary Wiring ...