FSG/MTM/001 060511
79
4. CCD-Cameras
The adjustment procedures presented in this chapter cover all adjustments needed for
replacing the complete CCD-camera.
It will hardly ever be necessary to replace mechanical parts such as Lens, Camera Housing,
etc., and in most cases, the only adjustments necessary after replacement of the CBE/CBF-
Board are:
•
Check Scan-Width. If it is within the limits given in Section 4.2.5, page
99, then Focus will also be OK.
•
CCD-Centering, Section 4.2.6 page 109
•
Vertical Positioning, Section 4.2.7, page 110
•
Run Scanner Maintenance, Section 6.1.7, page 142 to do
Vertical Alignment and Stitching
Basic and Color Calibration
These adjustments can be made without loosening the Camera Fixing Screws and
without loosening the Focus Lock Ring / Lock Screw.
4.1 Description of CCD-Cameras
See:
Fig. 4-1 Focus Lock Mechanism, page 82
Fig. 4-2 CCD-Camera, Side View, page 83
Fig. 4-3 CCD-Camera, Top View, page 84
The CCD-Camera basically consist of:
•
Lens
•
Lens Adapter
•
Camera Housing
•
Camera Back-Plate
•
CCD Mounting Plate
•
CBE/CBF-Camera Board
•
Camera Base Plate
•
Camera Motor, on Adjustable Cameras only
The parts of the CCD-Camera are mounted on a Camera Base Plate, and the complete CCD-
Camera is mounted on a Mounting Platform, which is welded to the scanner chassis. The
Camera is positioned with the optical axis perpendicular to the scan-area by means of two
guide pins extending from the bottom of the Base Plate down into two slots in the Mounting
Platform.
When the three Camera Fixing Screws are loosened for Camera Adjustment, two tension
springs pull the Camera Base Plate down against the Mounting Platform. Another spring pulls
the CCD-Camera in forward direction to keep the Scan Width Adjustment Screw in contact
with the scanner chassis, and to the left to align the guide pins with the left edge of the slots in
the Mounting Platform.
Summary of Contents for CHAMELEON 25
Page 69: ...FSG MTM 001 060511 65 Fig 3 21 OIBA Component Layout Fig 3 20 OSB Component Layout ...
Page 102: ...FSG MTM 001 060511 98 Fig 4 19 COUGAR Tx 36 CHAMELEON Tx 36 PREMIER Tx 36 Focus Signals ...
Page 106: ...FSG MTM 001 060511 102 Fig 4 20 COUGAR 25 CHAMELEON 25 Scan Width ...
Page 109: ...FSG MTM 001 060511 105 Fig 4 25 CHROMA Tx 40 CRYSTAL Tx 40 Scan Width Camera C ...
Page 118: ...FSG MTM 001 060511 114 Fig 4 32 COUGAR 25 CHAMELEON 25 CCD Centering and Vertical Positioning ...
Page 183: ...FSG MTM 001 060511 179 Fig 11 1 COUGAR 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 185: ...FSG MTM 001 060511 181 Fig 11 3 CHAMELEON 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 187: ...FSG MTM 001 060511 183 Fig 11 5 COUGAR 36 Primary Wiring WHITE SMPS WHITE LME L N WHITE ...
Page 193: ...FSG MTM 001 060511 189 Fig 11 11 MAGNUM XL 54 Primary Wiring ...
Page 194: ...FSG MTM 001 060511 190 Fig 11 12 MAGNUM XL 54 Secondary Wiring ...
Page 205: ...FSG MTM 002 060511 7 Fig 2 1 COUGAR Sx 25 and CHAMELEON Sx 25 Block Diagram ...
Page 207: ...FSG MTM 002 060511 9 Fig 2 2 CHROMA XL 42 and CRYSTAL XL 42 Block Diagram ...
Page 241: ...FSG MTM 002 060511 43 Fig 6 1 Sx 25 Primary Wiring ...
Page 242: ...FSG MTM 002 060511 44 Fig 6 2 Sx 25 Secondary Wiring ...
Page 243: ...FSG MTM 002 060511 45 Fig 6 3 XL 42 Primary Wiring ...
Page 244: ...FSG MTM 002 060511 46 Fig 6 4 XL 42 Secondary Wiring ...