FSG/MTM/001 060511
147
7.2 LED Indicators on Operator Panel
Power LED (Green and Red)
Booting and Power-On-Self-Test:
Yellow (Green & Red ON)
Warm Up
Green
Power ON (Operating mode)
Green
Low Power mode (Sleep mode)
Red
Scanner in Test mode (SCANtest 6)
OFF
Diagnostic LED (Red)
Booting and Power-On-Self-Test:
Red
Warm Up
OFF
Normal Operation
OFF
Scanner in Test mode (SCANtest 6)
Red
Error Condition, see Section 7.3.1 below.
Blinking
Wait LED (Yellow)
Media Thickness Setting
Normal
Extended Thickness
Booting and Power-On-Self-Test:
Yellow
Yellow
Warm Up
Yellow
Yellow
Normal Operation:
OFF
OFF
Automatic update of Light Profile
Correction has been suspended for
a period exceeding the built-in
update-timer or the scanner has
been switched ON with the
Original Guide Plate set for
Extended Thickness.
Blinking
Hint: May also occur during
intensive scanning in batch mode
or if original Exit and Entry
Sensors are both activated during
power on.
Blinking
Hint: Lower Original Guide Plate
to Normal position to allow Light
Profile Correction to be done.
Error Condition, Diagnostic is
blinking, see Section 7.3.1 below.
Blinking
Blinking
Ready LED (Green and Red)
Media Thickness Setting
Normal
Extended Thickness
Booting and Power-On-Self-Test:
Yellow
(Red & Green ON)
Yellow
(Red & Green ON)
Warm Up
OFF
OFF
No media
OFF
Red
Media inserted
Green
Yellow
(Red & Green ON)
Scanning Blinking
Green / OFF
Blinking
Yellow / Red
ATAC mode
(MAGNUM XL 54 only)
Blinking
Yellow / OFF
Blinking
Yellow / OFF
Error Condition: Diagnostic LED is
blinking, see Section 7.3.1 below.
Blinking
Green / OFF
Blinking
Green / OFF or Yellow/Red
7.3 Error Codes
7.3.1
Error Codes displayed on the Operator Panel
A blinking Diagnostic Indicator indicates an error condition. The error may be identified by
an Error Code Number being displayed on the screen and/or by the following combinations of
blinking (F) indicators on the Operator Panel:
Summary of Contents for CHAMELEON 25
Page 69: ...FSG MTM 001 060511 65 Fig 3 21 OIBA Component Layout Fig 3 20 OSB Component Layout ...
Page 102: ...FSG MTM 001 060511 98 Fig 4 19 COUGAR Tx 36 CHAMELEON Tx 36 PREMIER Tx 36 Focus Signals ...
Page 106: ...FSG MTM 001 060511 102 Fig 4 20 COUGAR 25 CHAMELEON 25 Scan Width ...
Page 109: ...FSG MTM 001 060511 105 Fig 4 25 CHROMA Tx 40 CRYSTAL Tx 40 Scan Width Camera C ...
Page 118: ...FSG MTM 001 060511 114 Fig 4 32 COUGAR 25 CHAMELEON 25 CCD Centering and Vertical Positioning ...
Page 183: ...FSG MTM 001 060511 179 Fig 11 1 COUGAR 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 185: ...FSG MTM 001 060511 181 Fig 11 3 CHAMELEON 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 187: ...FSG MTM 001 060511 183 Fig 11 5 COUGAR 36 Primary Wiring WHITE SMPS WHITE LME L N WHITE ...
Page 193: ...FSG MTM 001 060511 189 Fig 11 11 MAGNUM XL 54 Primary Wiring ...
Page 194: ...FSG MTM 001 060511 190 Fig 11 12 MAGNUM XL 54 Secondary Wiring ...
Page 205: ...FSG MTM 002 060511 7 Fig 2 1 COUGAR Sx 25 and CHAMELEON Sx 25 Block Diagram ...
Page 207: ...FSG MTM 002 060511 9 Fig 2 2 CHROMA XL 42 and CRYSTAL XL 42 Block Diagram ...
Page 241: ...FSG MTM 002 060511 43 Fig 6 1 Sx 25 Primary Wiring ...
Page 242: ...FSG MTM 002 060511 44 Fig 6 2 Sx 25 Secondary Wiring ...
Page 243: ...FSG MTM 002 060511 45 Fig 6 3 XL 42 Primary Wiring ...
Page 244: ...FSG MTM 002 060511 46 Fig 6 4 XL 42 Secondary Wiring ...