![Contex CHAMELEON 25 Technical & Service Manual Download Page 168](http://html1.mh-extra.com/html/contex/chameleon-25/chameleon-25_technical-and-service-manual_2656521168.webp)
FSG/MTM/001 060511
164
When replacing: Make sure that the cylinder shaped nut on the spindle rests correctly in the
cutout of the Vertical Alignment Arm. The Motor Bracket should be pushed to the uppermost
position when tightening the fixing screws to ensure sufficient tension of the drive belt.
The Camera Motor (Bracket) is now free to be removed.
Run SCANtest 6, Test 11 or Scanner Maintenance (Vertical Alignment).
9.7 Camera Board, CBE/CBF
Note: The Camera Board includes Mounting Plate and CCD, these parts should never be
disassembled
,
Remove the Original Guide Plate.
Remove the Top Cover.
Disconnect ribbon cable from the CBE/CBF-Board.
Remove the Camera Motor.
Remove the four fixing nuts for the CCD Mounting Plate, see Fig. 4-3, page 84.
The Camera Board (with Mounting Plate) is now free to be removed.
After replacement of CBE/CBF-Board, do:
•
CCD-Centering, Section 4.2.6, page 109.
•
Vertical Positioning, Section 4.2.7, page 110.
•
Check Scan-Width, if it is within the limits given in Section 4.2.5, page 99, Focus
will also be OK, and no further adjustments are required.
•
Run Scanner Maintenance, Section 6.1.7, page 142.
These adjustments can be made without loosening the Camera Fixing Screws and
without loosening the Focus Lock Ring / Lock Screw.
9.8 Lamp Sensor Board, OSB
Remove all Covers.
Remove the Mirror Chassis.
There is now free access to the Lamp Sensor Board.
After replacement:
Readjust the Lamp Driver, Section 3.4.2, page 30.
Check Camera Adjustment, Chapter 4.2, page 86
, especially Vertical Positioning, Section
Run Scanner Maintenance.
Summary of Contents for CHAMELEON 25
Page 69: ...FSG MTM 001 060511 65 Fig 3 21 OIBA Component Layout Fig 3 20 OSB Component Layout ...
Page 102: ...FSG MTM 001 060511 98 Fig 4 19 COUGAR Tx 36 CHAMELEON Tx 36 PREMIER Tx 36 Focus Signals ...
Page 106: ...FSG MTM 001 060511 102 Fig 4 20 COUGAR 25 CHAMELEON 25 Scan Width ...
Page 109: ...FSG MTM 001 060511 105 Fig 4 25 CHROMA Tx 40 CRYSTAL Tx 40 Scan Width Camera C ...
Page 118: ...FSG MTM 001 060511 114 Fig 4 32 COUGAR 25 CHAMELEON 25 CCD Centering and Vertical Positioning ...
Page 183: ...FSG MTM 001 060511 179 Fig 11 1 COUGAR 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 185: ...FSG MTM 001 060511 181 Fig 11 3 CHAMELEON 25 Primary Wiring WHITE LME WHITE SMPS L N WHITE ...
Page 187: ...FSG MTM 001 060511 183 Fig 11 5 COUGAR 36 Primary Wiring WHITE SMPS WHITE LME L N WHITE ...
Page 193: ...FSG MTM 001 060511 189 Fig 11 11 MAGNUM XL 54 Primary Wiring ...
Page 194: ...FSG MTM 001 060511 190 Fig 11 12 MAGNUM XL 54 Secondary Wiring ...
Page 205: ...FSG MTM 002 060511 7 Fig 2 1 COUGAR Sx 25 and CHAMELEON Sx 25 Block Diagram ...
Page 207: ...FSG MTM 002 060511 9 Fig 2 2 CHROMA XL 42 and CRYSTAL XL 42 Block Diagram ...
Page 241: ...FSG MTM 002 060511 43 Fig 6 1 Sx 25 Primary Wiring ...
Page 242: ...FSG MTM 002 060511 44 Fig 6 2 Sx 25 Secondary Wiring ...
Page 243: ...FSG MTM 002 060511 45 Fig 6 3 XL 42 Primary Wiring ...
Page 244: ...FSG MTM 002 060511 46 Fig 6 4 XL 42 Secondary Wiring ...