CAUTION!
Make sure that the antenna (4) and at the carbon brushes (5) make contact with the current-
collecting head (1).
Tighten the 2 hexagonal-socket-headed screws (3; see Fig. 63).
Fig. 66: Inserting the current-collecting head into the ProfiDAT
®
profile
Insert the current-collecting head (1) into the ProfiDAT
®
profile (2) from below.
8.2.3
Maximum Wear of the Carbon Brushes
WARNING!
Destruction of the system due to lack of grounding!
Carbon brushes that have been worn down beyond the permitted limit can no longer make
good contact with the ProfiDAT
®
profile. Poor contact between carbon brush and profile leads
to the loss of the PE connection (ground)! In case of a short circuit, the system is not
grounded.
Regularly check the degree of wear of the carbon brushes.
Under no circumstances continue to use defective or worn out carbon brushes.
Worn out carbon brushes must be exchanged immediately.
Fig. 67: Wear limit of the carbon brush on the ProfiDAT
®
current collector