Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 58 of 82
Fig. 56: Marking the cutting points on the insulating profile
Starting from the marked position, make one marking to the left and another to the right at 70 mm each.
Mark the two sections A and B so that they are not confused during installation.
Cut the marked gap out of the insulating profile. When doing this, insert a surplus piece of ProfiDAT
®
profile (a profile offcut,
for example) into the insulating profile so that it does not break during the cutting process. See also chapter 6.4.7.
Fig. 57: Installing the PE rail connector
Push section A onto the aluminum profile.
Push a PE rail connector (10) onto the aluminum profile and align it with the marking.
Secure the PE rail connector (10) with the threaded pins (3).
Tighten the four lateral flange screws (2) on the connector.
Push section B onto the aluminum profile.
Push the hanger clamps (6) back onto the ProfiDAT
®
profile (1).
Insert the ProfiDAT
®
profile (1) with hanger clamps (6) into the support structure (9) from below and secure the hanger clamps
with the nut (7) and the washer (8) (see Fig. 55).
Reconnect the profile with the adjacent profiles on the right and the left. To do this, push the rail connectors onto the profile as
far as the center of the connector, secure with the threaded pins and tighten the four lateral flange screws on the connector.
See chapter
Connect the PE cable, see chapter
A
B
A
B
2
10
3