Mounting Instructions
ProfiDAT
®
Data Transmission System
Programm 0514
MAL0514-0005b-EN
www.conductix.com
translated document
page 67 of 82
No.
Description
Remark: OK/not OK
1.
Installation
1.1.
The number of profile hanger clamps is correct (with a maximum spacing of 2500 mm).
1.2.
The expansion elements are correctly installed.
1.3.
The ProfiDAT
®
profiles are correctly aligned.
1.4.
The current collector is correctly installed. The force between the carbon brushes and the Profi-
DAT
®
profile is 28 N.
1.5.
The current collector is correctly aligned to the ProfiDAT
®
profile.
1.6.
There are no objects blocking the movement range of the current collector.
1.7.
The ProfiDAT
®
connectors are correctly installed (maximum gap of 0.5 mm between profiles;
no vertical or horizontal offset).
1.8.
The infeed modules/infeed unit are/is correctly installed.
1.9.
The terminating unit is correctly installed.
1.10.
The protective conductor cable at the start of the ProfiDAT
®
profiles is correctly installed.
1.11.
The protective conductor cables are correctly installed on the PE connectors.
1.12.
The carbon brushes are free of grease.
1.13.
The trace-heating system has been correctly installed (if an optional heating system has been
installed).
1.14.
All screws have been tightened according to the specification.
1.15.
The ProfiDAT
®
transceivers have been correctly installed.
1.16.
The ProfiDAT
®
infeed cabinet has been correctly installed.
1.17.
All electrical connections have been correctly completed by specialist personnel.
1.18.
All RF cables have been correctly installed.
1.19.
The operating personnel have been trained.
2.
ProfiDAT
®
connection
2.1.
The stationary ProfiDAT
®
transceiver is switched on and the LAN is connected
Switch on the 24-V power supply to the ProfiDAT
®
transceiver and allow the ProfiDAT
®
trans-
ceiver at least 1 minute to load.
Condition:
“ON” LED is green or flashing orange.
“LAN” LED is green.