During a load cycle, this page displays the two containers representation with the following indications:
Information details:
①
Twistlock weight:
Each Twistlock weight in tonnes.
②
Current container weight:
The current measured container weight in tonnes. The current measured added weight of both containers, displayed on the top
centre of the page.
③
Stabilized container weight:
The stabilized weight of each container and the total stabilized weight of both containers in tonnes (determined after the
weighing process).
④
Centre of gravity:
The centre of gravity of each container and from the spreader. The eccentricities of each container and of the spreader in %
(X: longitudinal and Y: transversal).
⑤
Weighing state:
Weighing in progress:
green when the LASSTEC system measure the weight and white when not.
Telescopic position:
indicate the telescopic position of the spreader in feet. Available if the spreader signals are fed into the
interrogator.
Lock:
red when the spreader Twistlocks are in lock position and white when the spreader Twistlocks are not in lock position.
Unlock:
green when the spreader Twistlocks are in unlock position and the system does not measure the weight. White when
the spreader Twistlocks are not in unlock position.