Status/Alarm
words
Status/Alarm
bits
Description
11
SLED temperature alarm
12
FILTER temperature alarm
13
Ramp setting alarm
14
Bad data in the RAM RTC alarm
15
Global alarm
Alarm 2
0
2nd
overload alarm Container 1
1
2nd
overload alarm Container 2
1)
2
1st
overload alarm Container 1
3
1st
overload alarm Container 2
1)
4
Container 1 over excentricity X alarm
5
Container 1 over excentricity Y alarm
6
Container 2 over excentricity X alarm
1)
7
Container 2 over excentricity Y alarm
1)
8
Container 1 + 2 overload alarm
1)
9
Container 1 + 2 Excentricity X
1)
10
Container 1 + 2 Excentricity Y
1)
11
Alarm: No input “lock or unlock” enable for more than 3 seconds
12
Alarm: Input “twinlift down” enable in single-lift mode
2)
13
RTC power supply lost alarm. The Interrogator was initialised without correct value into the
power up memory.
14
Low voltage 24V alarm
15
Container 1 + 2 overload Pre-alarm in twin mode
1)
Alarm 3
0
Snag load alarm on Twistlock 1
1
Snag load alarm on Twistlock 2
2
Snag load alarm on Twistlock 3
3
Snag load alarm on Twistlock 4
4
Snag load alarm on Twistlock 5
1)
5
Snag load alarm on Twistlock 6
1)
6
Snag load alarm on Twistlock 7
1)
7
Snag load alarm on Twistlock 8
1)
8
Event on container 1
9
Event on container 2
1)
10
Snag Alarm on container 1
11
Snag Alarm on container 2
1)
12
Snag Alarm on container 1 or 2
1)
13
Dragging alarm
14
Trailor lift alarm
15
No container size input detected
Alarm 4
0
No load alarm on TL1. No load is measured on Twistlock 1 despite it is measured on the other
Twistlocks.