Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 38 of 123
①
Twistlock number.
There you select the Twistlock you want to calibrate. With a single system you will have to calibrate 4 and with a twin system 8
Twistlocks.
②
Sensor coefficient
.
There you can enter the coefficient of the sensor. It has been determined by the sensor manufacturer and can be provided by
Conductix-Wampfler if needed.
③
Twistlock diameter
.
There you can specify the diameter [mm] of the Twistlock.
④
Twistlock coefficient
.
Displays the calculated overall Twistlock coefficient
⑤
Enable Twistlock Young’s modulus.
By selecting
Standard Young’s modulus
or
Known
Young’s modulus
you can define if the program uses either a predefined
value for the modulus (193 [GPa]) or one you can specify (see next point) according to the manufacturer’s specifications
⑥
Twistlock Young’s modulus [GPa].
When
Known Young’s modulus
is selected this is where you can specify the value of the Twistlock Young’s modulus according
to the manufacturer’s specifications.