Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 87 of 123
⑥
Date and Time:
Current date and time.
⑦
Datalogging:
A recorded pictogram: appear when the datalogging of the current load cycle is in progress and then: when the
datalogging is done.
Alarm indication:
Alarms:
Snag load alarm individual for each Twistlock (blinking “SNAG LOAD” indication and red background of the concerned Twistlock
weight).
Over-eccentricities alarms for each container (X-; X+; Y-; Y+; blinking “OVER ECCENTRICITY” indication according to the side
of the alarm).
Over-eccentricities alarms for the spreader (X-; X+; Y-; Y+; blinking “OVER ECCENTRICITY” indication according to the side of
the alarm).
Limit load alarm individually for each container (or 1
st
overload alarm; blinking “LIMIT LOAD” indication, yellow background of the
concerned current container weight and the concerned container become yellow).
Limit load alarm for the spreader (or 1
st
overload alarm; blinking “LIMIT LOAD” indication, yellow background of the total current
weight and both containers become yellow).
Overload alarm individually for each container (blinking “OVERLOAD” indication, red background of the concerned current
container weight and the concerned container become red).
Overload alarm for the spreader (blinking “OVERLOAD” indication, red background of the total current weight and both containers
become red).
A trailer lift alarm appears when the system detects a lifted trailer.
Dragging Alarm (blinking “DRAGGING” indication).
Not Carrying Twistlock (blinking “NOT CARRYING” indication, for each Twistlock).