Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 31 of 123
5.3.7.2.2.3
Twistlock Load & Overload Sub Tab
③
Function enable
Indicates if the function is active or not
Customer function enable
Indicates if the function is active by the costumer or not
Minimum alarm time for eccentricity
alarm [s]
Minimum time for which the alarm remains active
Threshold of load
Displays the threshold for the 1
st
overload alarm
Threshold of Overload
Displays the threshold for the 2
nd
overload alarm
5.3.7.2.2.4
Dragging sub tab
④
Function enable
Indicates if the function is active or not.
Customer function enable
Indicates if the function is active by the costumer or not.
Twistlock weight [Ton]
Configuration parameters for the dragging function.
Time before detection [s]
Minimum alarm timer [s]
5.3.7.2.2.5
Snag load sub tab
⑤
Function enable
Indicates if the function is active or not.
Customer function enable
Indicates if the function is active by the costumer or not.
Threshold snag load detection
container 1 [Ton]
Configuration parameters for the dragging function.
Threshold snag load detection
container 2 [Ton]
Event counter to detect s snag load
Minimum alarm time for Twistlock
snag load [s]
Minimum time for which the alarm remains active.
Minimum alarm time for container
snag load [s]
Minimum total weight to enable the snag load detection [Ton]
20 ft telescopic position
Weight limit which activates the function.
30 ft telescopic position
35 ft telescopic position
40 ft telescopic position
45 ft telescopic position