68
Performance and Operating Data
Condair GS
xxxxxxx_A_EN_1905_Condair-GS_OM
9
Performance and Operating Data
9.1
Performance Data
Model
Minimum Input
Maximum Input
Min./Max. Steam
Capacity
(kg/h)
Natural Gas (G20)
(kW)
Propane (G31)
(kW)
Natural Gas (G20)
(kW)
Propane (G31)
(kW)
GS 23-CS
3.6
3.6
18.2
18.2
4.6-23
GS 23
4.1
4.1
20.5
20.5
4.6-23
GS 45-CS
7.3
7.3
36.4
36.4
9-45
GS 45
8.2
8.2
41.0
41.0
9-45
GS 65-CS
10.9
10.9
54.5
54.5
13-65
GS 65
12.3
12.3
61.5
61.5
13-65
GS 90-CS
7.3
7.3
72.7
72.7
9-90
GS 90
8.2
8.2
82.0
82.0
9-90
GS 130-CS
10.9
10.9
109.0
109.0
13-136
GS 130
12.3
12.3
123.0
123.0
13-136
GS 195-CS
10.9
10.9
163.5
163.5
13-195
GS 195
12.3
12.3
184.5
184.5
13-195
GS 260-CS
10.9
10.9
218.0
218.0
13-260
GS 260
12.3
12.3
246.0
246.0
13-260
9.2
Operating Data
Control Signal Input Type:
Active
0-5 VDC, 1-5 VDC, 0-10 VDC, 2-10 VDC, 0-20 VDC, 0-16 VDC, 3.2-16 VDC,
0-20 mADC, 4-20 mADC
Passive
135-10 kΩ ohmic humidity sensor
On/Off control
<2.5 VDC Off
2.5-20 VDC On
Digital inputs (via Modbus, BACnet IP/
MSTP slave)
BACnet IP, BACnet MSTP Slave, Modbus, LonWorks (Option), BACnet MSTP
BTL-Certified (Option), BACnet IP BTL-Certified (Option)
Ambient Conditions:
Ambient temperature
5-40 °C
Relative humidity
5-80% (non-condensing)
Combustion Air:
Combustion air maximum temperature
30 °C
Backpressure:
Maximum permissible backpressure
(duct static pressure and line backpres
-
sure)
1.49 kPa compact unit
2.49 kPa full-size unit