Chapter
3 -
Using the Command Line Interface (CLI)
3-41
Vipersat Configuration
Figure 3-54
Minimum Power Level prompt (CDM-570L)
The value entered sets the minimum power level allowed by all SCPC modula-
tors.
Max Step Down Power
The
Maximum Step Down Power
value sets the largest step reduction in trans-
mit power permitted when the DPC is adjusting the power downward to achieve
the target set point. The default value for this parameter is 3 dB.
Enter
D
at the command prompt to display the Max Step Down Power dialog
shown in figure 3-55.
Figure 3-55
Maximum Step Down Power prompt
Max Step Up Power
The
Maximum Step Up Power
value sets the largest step increase in transmit
power permitted when the DPC is adjusting the power upward to achieve the
target set point. The default value for this parameter is 3 dB.
Enter
U
at the command prompt to display the Max Step Up Power dialog
shown in figure 3-56.
Figure 3-56
Maximum Step Up Power prompt