Chapter
3 -
Using the Command Line Interface (CLI)
3-13
Vipersat Configuration
Figure 3-12
Cycles per Burst Map prompt
Slot Guardband
This menu item displays the current length of the slot guardband in milli-
seconds and the size of the guardband in bytes for the target CDM-570/570L.
Figure 3-13
Slot Guardband prompt
On a Hub unit, this value can be modified by entering
G
at the command
prompt to display the dialog shown in figure 3-13 and entering a new value.
On Remote units, this menu item is an information-only display.
Note:
Note that the value you enter at the command line in figure 3-13
is in milliseconds. The corresponding value expressed in bytes is
calculated by the CDM-570/570L based on the STDMA transmit
bit rate as shown in the menu in figure 3-6.
Slot Preamble Length
This menu item displays the current slot preamble size in milli-seconds and
bytes for the target CDM-570/570L.
Figure 3-14
Slot Preamble Length prompt
On a Hub unit, entering
P
at the command prompt allows changing the pream-
ble duration in milliseconds.
On Remote units, this menu item is an information-only display.
NOTE
Summary of Contents for Vipersat CDM-570L
Page 2: ......
Page 6: ... This Page Intentionally Blank ...
Page 10: ...iv Vipersat CDM 570 570L User Guide ...
Page 22: ...Customer Support 1 10 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 86: ...Vipersat Configuration 3 52 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 120: ...C 6 Vipersat CDM 570 570L User Guide This Page Intentionally Blank ...
Page 136: ...Firmware Upgrade D 16 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 146: ...E 10 Vipersat CDD 564L User s Guide This Page Intentionally Blank ...