C-4
Vipersat CDM-570/570L User Guide
DPC Scaling Function
Figure C-1
DPC Scaling Function
Figure C-1 illustrates the scaling function, based on the ratio of power level to
data rate, of the DPC system. Once this ratio is mapped out for the system, the
DPC scaling function will automatically determine the appropriate power level
for any given data rate. Three parameters are essential for this scaling function:
•
Calibrated Data Rate
•
Calibrated Nominal Power Level
•
Maximum Power Level
As determined during initial system turn-up, the Calibrated Data Rate and the
Calibrated Nominal Power Level values for the CDM are entered into the VMS
Home State
menu. The Maximum Power Level (the point at which the signal
reaches saturation) for the Calibrated Data Rate is then determined, and entered
into the VMS
DPC
menu (or the CLI
Dynamic Power Control Configuration
menu). If these home state parameters have not been entered, DPC will not be
Max Power
(Saturation)
Calibrated
Nominal Power
Level
Current (Scaled)
Max Power
Current
Data Rate
Calibrated
Data Rate
Data Rate
P
ower Le
vel
Max Ratio
Nominal Ratio
Summary of Contents for Vipersat CDM-570L
Page 2: ......
Page 6: ... This Page Intentionally Blank ...
Page 10: ...iv Vipersat CDM 570 570L User Guide ...
Page 22: ...Customer Support 1 10 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 86: ...Vipersat Configuration 3 52 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 120: ...C 6 Vipersat CDM 570 570L User Guide This Page Intentionally Blank ...
Page 136: ...Firmware Upgrade D 16 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 146: ...E 10 Vipersat CDD 564L User s Guide This Page Intentionally Blank ...