Initial Configuration
2-4
Vipersat CDM-570/570L User Guide
Setting Vipersat CDM-570/570L Operating
Parameters
The following is an example of using the CLI to bring a Vipersat CDM-570/
570L with factory default settings to the configuration which allows the Viper-
sat functions to be accessible.
When the parameter file (
param image
) of the CDM-570/570L has either been
reset to or still has the factory default configuration, all Vipersat feature and
unlock codes in the CDM-570/570L are deleted and all configurations are reset,
disabling the Vipersat feature set.
Set the Feature Configuration
The operating parameters that will be configured in the target CDM-570/570L
are, in part, determined by the role the CDM-570/570L is to fill in the network,
as shown in table 2-1 and table 2-2.
Use the following procedure to configure a CDM-570/570L to the network role
it is to fill in a Vipersat network.
1.
From the
Main Menu
shown in figure 2-1, select the
Administration
command by entering
A
at the command prompt.
Table 2-1
CDM-570/570L Network Roles and Functions
CDM-570/570L Network Role/Function
Hub Remote Expansion
Hub Burst Controller providing STDMA Timing Maps
X
Hub Point-to-Point SCPC Modem
X
Hub Switched Demodulator
X
X
Remote STDMA Modem
X
Remote Point-to-Point SCPC Modem
X
Remote Mesh Demodulator
X
X
Summary of Contents for Vipersat CDM-570L
Page 2: ......
Page 6: ... This Page Intentionally Blank ...
Page 10: ...iv Vipersat CDM 570 570L User Guide ...
Page 22: ...Customer Support 1 10 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 86: ...Vipersat Configuration 3 52 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 120: ...C 6 Vipersat CDM 570 570L User Guide This Page Intentionally Blank ...
Page 136: ...Firmware Upgrade D 16 Vipersat CDM 570 570L User Guide This Page is Intentionally Blank ...
Page 146: ...E 10 Vipersat CDD 564L User s Guide This Page Intentionally Blank ...