5-12
Remote Commands and Error Codes
STP
Secondary
Transmit Path
Config (NV)
Consists of entry slot, data slots,
and exit slot for data path.
—
Sets secondary transmit path.
SWV
Module Software
Version
Monitor
syntax is n:SWV ? where
n = 1, 4, 5
—
Displays the card’s software version by slot;
response format: <slot#>:V<version number>.
TC
Transmit Code
Rate
Config (NV)
0 = uncoded, rate 1
1 = Sequential, rate 1/2
2 = Sequential, rate 3/4
3 = Viterbi, rate 1/2
4 = Viterbi, rate 3/4
5 = Viterbi, rate 7/8
3
Sets the type and rate of FEC decoding
performed by modulator.
TD
Transmit Data Rate
Config (NV)
4800 to 512000 bps
9600
Establish the data rate that is input to the
modulator for transmission; rate is the transmit
data rate expected at the user data I/O
connector (TT and SD signals), unless the
CM601 is configured with an optional
intermediate data processing card; recommend
using PTD command rather than TD.
TDI
Transmit Data
Invert
Config (NV)
0 = true data
1 = inverts data
0
Specifies if data received from the DTE by the
I/O card is to be inverted or not.
TIM
Real-time Clock
Config (NV)
000000 to 235959
—
Sets the CM601 real-time clock; time is factory
set to U.S.A. Pacific standard time; no default;
IN 9346 or INF 9346 does not reset values in
NV memory; parameters expressed in two-digit
format - hours, minutes, and seconds.
TIO
Transmit Data I/O
Card
Config (NV)
0 = data I/O connector on modem
card
1 = corresponds to slot 1
1 if data I/O
card in slot 1
Selects active transmit I/O card by slot number
for CM601 configurations with multiple data
interface cards installed.
TM
Transmit
Modulation Type
Config (NV)
0 = BPSK
1 = QPSK
0
Sets modulation type for modulator.
TP
Modulator Transmit
Power
Config (NV)
50 - 250
100
Sets the output power level of the modulator
TxIF in 0.1 dBm steps.
TR
Transmit Symbol
Rate
Config (NV)
4800 to 512000 sps
19200
Sets the modulator symbol rate; recommend
use of PTD command rather than TR.
TRD
Ternary Receive
Data Rate
Config (NV)
4800 to 512000 bps
0
Issues all appropriate receive data rate
commands to all option cards in the ternary
receive data path; accounts for any overhead
removed by a module from the data stream;
return value: 0 = no data rate entered for macro
or it no longer reflects system Tx or Rx data
rate.
TRP
Ternary Receive
Path
Config (NV)
Consists of entry slot, data slots,
and exit slot for data path.
—
Sets ternary receive data path.
TS
Transmit
Synthesizer
Frequency
Config (NV)
52000 to 88000
70000
Sets the IF carrier synthesizer frequency for the
modulator; changes in increments of 1 Hz.
TT
Transmit Timing
Clock Frequency
Monitor
?
—
Displays the frequency of the TT clock supplied
by the DTE to the data I/O connector of the
CM601; parameter accurate to better than ±1
percent of the frequency being measured.
Frequency of the TT clock is expressed in
hertz; if BEN = 1 then ER 4 displays.
Table 5-3
Command Summary (continued)
Command
Mnemonic
Command Name
Function
(Mem Type)
Parameter Range
Default
Description and Notes
Summary of Contents for CM601
Page 4: ...iv Notice COMSTREAM A Spar Company...
Page 12: ...xii Contents COMSTREAM A Spar Company...
Page 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Page 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Page 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Page 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Page 160: ...xii Safety Precautions 01 0799 401D 08 02...
Page 164: ...4 Functional Description 01 0799 401D 08 02...
Page 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Page 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Page 208: ...48 Loopback Tests 01 0799 401D 08 02...
Page 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Page 220: ...60 01 0799 401D 08 02...
Page 222: ...D 08 02 01 0799 401 Index 62...