5-10
Remote Commands and Error Codes
MQE
Modem Query
Execute
Monitor
?
—
Executes the current modem query list and
returns the first result buffer; this command is
available after you enter a modem query list
with the MQL command.
MQL
Modem Query List
Config (V)
One or more CM601 command
mnemonics, up to 120 characters
separated by commas
—
Combines multiple queries into single
command; list is executed by the MQE
command.
MQN
Modem Query Next Monitor
—
—
Displays the next modem query list result
buffer; when additional data remains in a
modem query list result buffer, the last
character of the first buffer response to the
MQE command is a plus sign (+).
NVO
Nonvolatile
Memory Override
Config (NV)
0 = normal operation
1 = NV override on
0
Inhibits writing to NV memory when a NV
command is entered.
OM
Override Modulator
Bit Time Fault
Config (NV)
0 = disables TxIF output
1 = does not disable TxIF output
0
Controls the automatic actions performed by
the modulator upon detection of a transmit bit
time fault.
PC
Pure Carrier
Config (V)
0 = normal, modulated
1 = pure, unmodulated
0
Forces the modulator to transmit an
unmodulated carrier.
PRD
Primary Receive
Data Rate
Config (NV)
4800 to 512000 bps
0
Issues all appropriate receive data rate
commands to all option cards in the primary
receive data path; accounts for any overhead
removed by a module from the data stream.
The PRD command represents the data rate
that is output from the active I/O card on the
receive side of the CM601.
PRP
Primary Receive
Path
Config (NV)
Consists of entry slot, data slots,
and exit slot for data path
—
Sets primary receive data path.
PTD
Primary Transmit
Data Rate
Config (NV)
4800 to 512000
—
Issues all appropriate transmit data rate
commands to all option cards in the primary
transmit data path; accounts for any overhead
added by a module to the data stream. The
PTD command represents the data rate that is
input to the active I/O card on the transmit side
of the CM601.
PTP
Primary Transmit
Path
Config (NV)
Consists of entry slot, data slots,
and exit slot for data path
—
Sets primary transmit data path.
RC
Receive Coding
Rate
Config (NV)
0 = uncoded, rate 1
1 = Sequential, rate 1/2
2 = Sequential, rate 3/4
3 = Viterbi, rate 1/2
4 = Viterbi, rate 3/4
5 = Viterbi, rate 7/8
3
Sets type and rate of FEC decoding performed
by demodulator.
RD
Receive Data Rate
Config (NV)
4800 to 512000
9600
Sets the data rate that is output by the
demodulator after demodulating and decoding
the receive signal. This rate is the receive data
rate, RT and RD signals, provided at the user
data interface, unless the CM601 is configured
with an SCC or some other intermediate data
processing card.
RDI
Receive Data
Invert
Config (NV)
0 = true data
1 = inverts data
0
Specifies if data received from demodulator
and sent to the user DTE equipment is inverted
or true.
Table 5-3
Command Summary (continued)
Command
Mnemonic
Command Name
Function
(Mem Type)
Parameter Range
Default
Description and Notes
Summary of Contents for CM601
Page 4: ...iv Notice COMSTREAM A Spar Company...
Page 12: ...xii Contents COMSTREAM A Spar Company...
Page 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Page 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Page 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Page 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Page 160: ...xii Safety Precautions 01 0799 401D 08 02...
Page 164: ...4 Functional Description 01 0799 401D 08 02...
Page 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Page 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Page 208: ...48 Loopback Tests 01 0799 401D 08 02...
Page 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Page 220: ...60 01 0799 401D 08 02...
Page 222: ...D 08 02 01 0799 401 Index 62...